Worked example
Example: Illustrative 127 couples at 4 A, 40/10 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Current | 4.0000 A |
| Hot-side temperature | 40.000 °C |
| Cold-side temperature | 10.000 °C |
| Seebeck coefficient per couple | 400.00 µV/K |
| Electrical resistance per couple | 0.010000 Ω |
| Thermal conductance per couple | 5.0000e-06 kW/K |
| Couples | 127.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cooling capacity | 0.028326 kW |
| Electrical input | 0.026416 kW |
| Coefficient of performance | 1.0723 |
| Module voltage | 6.6040 V |
| Current for maximum cooling S T_c/R | 11.326 A |
| Largest temperature difference ½ZT_c² | 128.28 K |
Open this example in the calculator and change any input.
Formula
\(\dot Q_c = n\left(SIT_c - \frac{1}{2}I^2R - K\Delta T\right), \quad P_{in} = n\left(SI\Delta T + I^2R\right), \quad \Delta T_{max} = \frac{1}{2}ZT_c^2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(I\) | Current | A |
| \(T_h\) | Hot-side temperature | K |
| \(T_c\) | Cold-side temperature | K |
| \(S\) | Seebeck coefficient per couple | V/K |
| \(R\) | Electrical resistance per couple | Ω |
| \(K\) | Thermal conductance per couple | W/K |
| \(n\) | Couples | - |
| \(\dot Q_c\) | Cooling capacity | W |
| \(P_{in}\) | Electrical input | W |
| \(COP\) | Coefficient of performance | - |
| \(V\) | Module voltage | V |
| \(I_{max}\) | Current for maximum cooling S T_c/R | A |
| \(\Delta T_{max}\) | Largest temperature difference ½ZT_c² | K |
Method and standards
Peltier cooling.
Where it is used
- Electronics and laser cooling.
- Small portable coolers.
Common mistakes
- Ignoring the heat sink's temperature rise.
- Running at maximum current for best efficiency.
Assumptions and limits
- Constant properties; ideal heat sinks.
References
- Thermoelectric cooling couple model
Questions and answers
Why is Peltier COP so low?
Joule heating and heat conduction back through the legs eat into the Peltier cooling; for ΔT of 30 K the COP is often below 1.
Is more current always better?
No: cooling peaks at I = ST_c/R and then falls as Joule heat grows, while power keeps rising, so the best COP is at a much lower current.
What do the defaults represent?
An illustrative 127-couple module (400 µV/K, 10 mΩ, 0.005 W/K per couple) at 4 A with 40 °C hot and 10 °C cold sides.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)