Worked example
Example: 1 k, 2 k, 500 Ω, Rx 1 010 Ω, 10 V. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Arm R₁ (top left) | 1,000.0 Ω |
| Arm R₂ (bottom left) | 2,000.0 Ω |
| Arm R₃ (top right) | 500.00 Ω |
| Fourth arm, actual value (bottom right) | 1,010.0 Ω |
| Supply voltage | 10.000 V |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fourth arm at balance R₂ R₃ / R₁ | 1,000.0 Ω |
| Bridge output voltage | 22.075 mV |
| Deviation of R_x from balance | 1.0000 % |
Open this example in the calculator and change any input.
Formula
\(R_{x,bal} = \frac{R_2 R_3}{R_1}, \quad V_o = V_s \left(\frac{R_x}{R_3 + R_x} - \frac{R_2}{R_1 + R_2}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(R_1\) | Arm R₁ (top left) | Ω |
| \(R_2\) | Arm R₂ (bottom left) | Ω |
| \(R_3\) | Arm R₃ (top right) | Ω |
| \(R_x\) | Fourth arm, actual value (bottom right) | Ω |
| \(V_s\) | Supply voltage | V |
| \(R_{x,bal}\) | Fourth arm at balance R₂ R₃ / R₁ | Ω |
| \(V_o\) | Bridge output voltage | V |
| \(\delta\) | Deviation of R_x from balance | - |
Method and standards
Two voltage dividers compared.
Where it is used
- RTD and strain gauge circuits.
- Laboratory resistance measurement.
Common mistakes
- Arms in the wrong position.
- Lead resistance ignored.
Assumptions and limits
- High-impedance detector.
References
- Wheatstone bridge balance R₁/R₂ = R₃/R_x
Questions and answers
What balances 1000, 2000 and 500 Ω?
R_x = 2000 × 500 / 1000 = 1000 Ω.
What output for R_x = 1010 Ω at 10 V?
22.1 mV.
Why use a bridge?
It measures small changes of resistance as a voltage around zero.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.