FireCADCalc

Parallel RLC Circuit: Currents, Impedance and Resonance

Branch currents, total current, impedance and power factor of a parallel RLC circuit at a frequency, with its resonant frequency and Q factor.

Inputs

Examples: 50 Hz, 100 Ω, 0.2 H, 40 µF, 230 V1 kHz, 1 kΩ, 10 mH, 1 µF, 10 V60 Hz, 50 Ω, 0.1 H, 100 µF, 120 V

Results

Inductive: the current lags the voltage (lagging power factor).

Current in the resistor2.3000A
Current in the inductor3.6606A
Current in the capacitor2.8903A
Total current2.4256A
Impedance94.823Ω
Power factor0.94823
Resonant frequency56.270Hz
Quality factor R √(C/L)1.4142

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 Hz, 100 Ω, 0.2 H, 40 µF, 230 V. The inputs, in the units selected above:

InputValue
Supply frequency50.000 Hz
Resistance100.00 Ω
Inductance200.00 mH
Capacitance40.000 µF
Supply voltage (rms)230.00 V

Applying the formula below gives:

ResultValue
Current in the resistor2.3000 A
Current in the inductor3.6606 A
Current in the capacitor2.8903 A
Total current2.4256 A
Impedance94.823 Ω
Power factor0.94823
Resonant frequency56.270 Hz
Quality factor R √(C/L)1.4142

Open this example in the calculator and change any input.

Formula

\(Y = \sqrt{\frac{1}{R^2} + \left(\omega C - \frac{1}{\omega L}\right)^2}, \quad I = V\, Y, \quad f_0 = \frac{1}{2\pi\sqrt{LC}}\)

Variables

Symbol Meaning SI unit
\(f\) Supply frequency 1/s
\(R\) Resistance Ω
\(L\) Inductance H
\(C\) Capacitance F
\(V\) Supply voltage (rms) V
\(I_R\) Current in the resistor A
\(I_L\) Current in the inductor A
\(I_C\) Current in the capacitor A
\(I\) Total current A
\(Z\) Impedance Ω
\(\cos\varphi\) Power factor -
\(f_0\) Resonant frequency 1/s
\(Q\) Quality factor R √(C/L) -

Method and standards

Admittances add in parallel.

Where it is used

  • Capacitor banks with inductive loads.
  • Filters.

Common mistakes

  • Adding branch currents arithmetically.
  • Series and parallel Q mixed up.

Assumptions and limits

  • Ideal components.
  • The power factor is given as a magnitude; a note says whether it is leading (capacitive, ωC > 1/ωL) or lagging (inductive).

References

  • AC circuit theory (admittances in parallel)

Questions and answers

What happens at resonance in a parallel circuit?

The inductor and capacitor currents cancel, so the supply sees only R: impedance is highest.

Is that power factor correction?

Yes: a capacitor in parallel with an inductive load cancels part of its lagging current.

What is Q here?

R √(C/L): the ratio of circulating to supply current at resonance.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.