First-order propagation with the assay errors independent (no covariance), Wills eq. 3.30. The error grows as concentrate and tailings assays approach each other: then reconcile the balance with more components or measured flows.

Metal recovery89.431%
Standard deviation of recovery1.0453%
95 % half-range of recovery2.0489%
Share of variance from the feed assay24.254%
Share from the concentrate assay0.015587%
Share from the tailings assay75.730%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Wills Example 3.9 zinc, assays to 0.05 / 0.5 / 0.02 % Zn. The inputs, in the units selected above:

InputValue
Feed assay3.9300 %
Concentrate assay52.070 %
Tailings assay0.49000 %
Standard deviation of the feed assay (absolute)0.050000 %
Standard deviation of the concentrate assay0.50000 %
Standard deviation of the tailings assay0.020000 %

Applying the formula below gives:

ResultValue
Metal recovery88.363 %
Standard deviation of recovery0.50558 %
95 % half-range of recovery0.99093 %
Share of variance from the feed assay10.032 %
Share from the concentrate assay0.025419 %
Share from the tailings assay89.942 %

Open this example in the calculator and change any input.

Formula

\(V_R = \left(\frac{\partial R}{\partial f}\right)^2 V_f + \left(\frac{\partial R}{\partial c}\right)^2 V_c + \left(\frac{\partial R}{\partial t}\right)^2 V_t, \quad R = \frac{c(f - t)}{f(c - t)}\)

Variables

Symbol Meaning SI unit
\(f\) Feed assay -
\(c\) Concentrate assay -
\(t\) Tailings assay -
\(\sigma_f\) Standard deviation of the feed assay (absolute) -
\(\sigma_c\) Standard deviation of the concentrate assay -
\(\sigma_t\) Standard deviation of the tailings assay -
\(R\) Metal recovery -
\(\sigma_R\) Standard deviation of recovery -
\(1.96\sigma_R\) 95 % half-range of recovery -
\(V_f\) Share of variance from the feed assay -
\(V_c\) Share from the concentrate assay -
\(V_t\) Share from the tailings assay -

Method and standards

First-order error propagation.

Where it is used

  • Planning assay precision for plant trials.
  • Judging whether a change in recovery is real.

Common mistakes

  • Entering relative instead of absolute standard deviations.
  • Trusting the recovery of a poorly separated metal.

Assumptions and limits

  • Independent, unbiased assay errors.

References

  • Wills and Finch
  • Wills' Mineral Processing Technology
  • 8th ed. (Butterworth-Heinemann, 2016)
  • ch. 3
  • eqs. 3.30-3.33 and Example 3.9

Questions and answers

Which assay matters most?

Usually the tailings assay: its coefficient is largest because the recovery depends on the small difference between feed and tailings.

Why is copper so poorly defined in Wills's example?

Copper is barely separated in a zinc circuit (0.66 % against 0.14 %), so the denominator c − t is small and errors multiply.

What do the defaults represent?

Wills's Example 3.9 zinc assays with standard deviations of 0.05, 0.5 and 0.02 % Zn on feed, concentrate and tailings.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.