FireCADCalc

Screen Passage Probability and Vibration g-Force

Gaudin's probability that a particle passes a square aperture, the open area, the chance of passing in n presentations, and the vibration g-force of the screen.

Inputs

Examples: 10 mm aperture, 2.5 mm wire, 7 mm particle, 20 presentationsFine screen 0.5 mm, near-mesh 0.45 mmCoarse scalper 50 mm, 20 mm rock

Results

Spherical particles and a single layer on the deck. Near-mesh particles (d/x above 0.75) need many presentations and tend to peg the apertures. Vibrating screens usually run at 3–7 g.

Above about 7 g particles bounce clear of the deck and get few chances to pass.

Open area fraction44.444%
Probability of passage in one presentation0.44444%
Probability of passing within n presentations19.966%
Expected presentations to pass225.00
Stroke (peak to peak)1.6000mm
Vibration g-force8.0486

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 mm aperture, 2.5 mm wire, 7 mm particle, 20 presentations. The inputs, in the units selected above:

InputValue
Aperture size (square)10.000 mm
Wire diameter2.5000 mm
Particle size7.0000 mm
Number of presentations to the deck20.000 -
Vibration amplitude (half the stroke)3.0000 mm
Vibration frequency15.000 Hz

Applying the formula below gives:

ResultValue
Open area fraction64.000 %
Probability of passage in one presentation5.7600 %
Probability of passing within n presentations69.471 %
Expected presentations to pass17.361
Stroke (peak to peak)6.0000 mm
Vibration g-force2.7164

Open this example in the calculator and change any input.

Formula

\(p = \left(\frac{x - d}{x + w}\right)^2 = f_o\left(1 - \frac{d}{x}\right)^2, \quad f_o = \frac{x^2}{(x + w)^2}, \quad \Gamma = \frac{a(2\pi\nu)^2}{9.81}\)

Variables

Symbol Meaning SI unit
\(x\) Aperture size (square) m
\(w\) Wire diameter m
\(d\) Particle size m
\(n\) Number of presentations to the deck -
\(a\) Vibration amplitude (half the stroke) m
\(\nu\) Vibration frequency 1/s
\(f_o\) Open area fraction -
\(p\) Probability of passage in one presentation -
\(1 - (1 - p)^n\) Probability of passing within n presentations -
\(1/p\) Expected presentations to pass -
\(2a\) Stroke (peak to peak) m
\(\Gamma\) Vibration g-force -

Method and standards

Gaudin's probability of passage.

Where it is used

  • Choosing aperture and wire for a duty.
  • Setting stroke and speed of vibrating screens.

Common mistakes

  • Using slotted-aperture openings in the square formula.
  • Confusing amplitude with stroke.

Assumptions and limits

  • Spheres, square apertures.

References

  • Wills and Finch
  • Wills' Mineral Processing Technology
  • 8th ed. (Butterworth-Heinemann, 2016)
  • ch. 8
  • eqs. 8.11-8.15 (Gaudin, 1939) and Table 8.1 (Taggart, 1945)

Questions and answers

Why is near-mesh material hard to screen?

The chance of passing falls with the square of the clearance: at 90 % of the aperture only about 1 particle in 100 presentations passes.

What is the g-force?

The peak acceleration of the deck divided by gravity: amplitude times the square of the angular frequency, over 9.81 m/s².

What do the defaults represent?

A 10 mm aperture with 2.5 mm wire, a 7 mm particle presented 20 times, 3 mm amplitude at 15 Hz.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.