Worked example
Example: 10 mm aperture, 2.5 mm wire, 7 mm particle, 20 presentations. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Aperture size (square) | 10.000 mm |
| Wire diameter | 2.5000 mm |
| Particle size | 7.0000 mm |
| Number of presentations to the deck | 20.000 - |
| Vibration amplitude (half the stroke) | 3.0000 mm |
| Vibration frequency | 15.000 Hz |
Applying the formula below gives:
| Result | Value |
|---|---|
| Open area fraction | 64.000 % |
| Probability of passage in one presentation | 5.7600 % |
| Probability of passing within n presentations | 69.471 % |
| Expected presentations to pass | 17.361 |
| Stroke (peak to peak) | 6.0000 mm |
| Vibration g-force | 2.7164 |
Open this example in the calculator and change any input.
Formula
\(p = \left(\frac{x - d}{x + w}\right)^2 = f_o\left(1 - \frac{d}{x}\right)^2, \quad f_o = \frac{x^2}{(x + w)^2}, \quad \Gamma = \frac{a(2\pi\nu)^2}{9.81}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x\) | Aperture size (square) | m |
| \(w\) | Wire diameter | m |
| \(d\) | Particle size | m |
| \(n\) | Number of presentations to the deck | - |
| \(a\) | Vibration amplitude (half the stroke) | m |
| \(\nu\) | Vibration frequency | 1/s |
| \(f_o\) | Open area fraction | - |
| \(p\) | Probability of passage in one presentation | - |
| \(1 - (1 - p)^n\) | Probability of passing within n presentations | - |
| \(1/p\) | Expected presentations to pass | - |
| \(2a\) | Stroke (peak to peak) | m |
| \(\Gamma\) | Vibration g-force | - |
Method and standards
Gaudin's probability of passage.
Where it is used
- Choosing aperture and wire for a duty.
- Setting stroke and speed of vibrating screens.
Common mistakes
- Using slotted-aperture openings in the square formula.
- Confusing amplitude with stroke.
Assumptions and limits
- Spheres, square apertures.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 8
- eqs. 8.11-8.15 (Gaudin, 1939) and Table 8.1 (Taggart, 1945)
Questions and answers
Why is near-mesh material hard to screen?
The chance of passing falls with the square of the clearance: at 90 % of the aperture only about 1 particle in 100 presentations passes.
What is the g-force?
The peak acceleration of the deck divided by gravity: amplitude times the square of the angular frequency, over 9.81 m/s².
What do the defaults represent?
A 10 mm aperture with 2.5 mm wire, a 7 mm particle presented 20 times, 3 mm amplitude at 15 Hz.