FireCADCalc

Mine Fan Operating Point on the Mine Characteristic

Air flow and fan pressure where a fan curve fitted through three points meets the mine characteristic p = R Q², with natural pressure, air power and shaft power.

Fan and blower

Inputs

Examples: Axial main fan, mine R 0.06 N s2/m8Same fan, natural pressure assisting 150 PaCentrifugal fan on a high-resistance mine

Results

The fitted parabola is reliable only between the three fan points; use the maker's full curve and avoid the stall region left of the pressure peak.

Operating air flow164.75m³/s
Fan pressure1,478.5Pa
Air power243.58kW
Fan shaft power324.78kW
Mine pressure drop1,628.5Pa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Axial main fan, mine R 0.06 N s2/m8. The inputs, in the units selected above:

InputValue
Fan curve point 1: flow100.00 m³/s
Point 1: fan pressure1,850.0 Pa
Point 2: flow150.00 m³/s
Point 2: fan pressure1,600.0 Pa
Point 3: flow200.00 m³/s
Point 3: fan pressure1,100.0 Pa
Mine resistance (N·s²/m⁸)0.060000 -
Natural pressure assisting the fan (negative opposing)0 Pa
Fan efficiency75.000 %

Applying the formula below gives:

ResultValue
Operating air flow159.42 m³/s
Fan pressure1,524.9 Pa
Air power243.10 kW
Fan shaft power324.14 kW
Mine pressure drop1,524.9 Pa

Open this example in the calculator and change any input.

Formula

\(p_f(Q) = c_0 + c_1 Q + c_2 Q^2 = R Q^2 - NVP, \quad P_s = \frac{p_f Q}{\eta}\)

Variables

Symbol Meaning SI unit
\(Q_1\) Fan curve point 1: flow m³/s
\(p_1\) Point 1: fan pressure Pa
\(Q_2\) Point 2: flow m³/s
\(p_2\) Point 2: fan pressure Pa
\(Q_3\) Point 3: flow m³/s
\(p_3\) Point 3: fan pressure Pa
\(R\) Mine resistance (N·s²/m⁸) -
\(NVP\) Natural pressure assisting the fan (negative opposing) Pa
\(\eta\) Fan efficiency -
\(Q\) Operating air flow m³/s
\(p_f\) Fan pressure Pa
\(p_f Q\) Air power W
\(P_s\) Fan shaft power W
\(RQ^2\) Mine pressure drop Pa

Method and standards

Intersection of fan and mine characteristics.

Where it is used

  • Main fan selection and blade-angle setting.
  • Predicting the effect of new workings.

Common mistakes

  • Using total and static fan pressures inconsistently.
  • Extrapolating the fan curve.

Assumptions and limits

  • Quadratic fan curve between the points.

References

  • Peele (ed.)
  • Mining Engineers' Handbook
  • 3rd ed. (Wiley, 1941)
  • sec. 14
  • Mine Ventilation
  • art. 15 (pressure-quantity characteristics of fans and mines) and art. 12 (natural draft)

Questions and answers

Why does natural pressure shift the duty?

Assisting natural draft lowers the pressure the fan must supply, so it delivers more air; opposing draft does the reverse.

What if the resistance rises?

The mine curve steepens and the point moves left to less air and more pressure, possibly into the fan's stall region.

What do the defaults represent?

An axial main fan giving 1,850, 1,600 and 1,100 Pa at 100, 150 and 200 m³/s on a mine of 0.06 N·s²/m⁸, 75 % efficient.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.