Worked example
Example: Coal-mine butt heading 6.2 x 9.2 ft (k 37e-10), 1 km, 20 m3/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Atkinson friction factor at 1.2 kg/m³ | 0.006865 kg/m³ |
| Perimeter of the airway | 9.3878 m |
| Length of the airway | 1,000.0 m |
| Cross-sectional area | 5.2992 m² |
| Sum of shock-loss factors (bends, obstructions) | 0 - |
| Air flow | 20.000 m³/s |
| Air density | 1.2000 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Friction resistance (N·s²/m⁸) | 0.43308 |
| Air velocity | 3.7742 m/s |
| Friction pressure drop | 173.23 Pa |
| Shock pressure drop | 0 Pa |
| Total pressure drop | 173.23 Pa |
| Air power | 3.4646 kW |
| Equivalent orifice | 1.8833 m² |
| Total resistance including shock (N·s²/m⁸) | 0.43308 |
Open this example in the calculator and change any input.
Formula
\(p = \frac{K O L}{A^3}\frac{\rho}{1.2}Q^2 + X\frac{\rho V^2}{2}, \quad R = \frac{p}{Q^2}, \quad A_{eq} = \frac{Q}{0.625\sqrt{2p/\rho}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(K\) | Atkinson friction factor at 1.2 kg/m³ | kg/m³ |
| \(O\) | Perimeter of the airway | m |
| \(L\) | Length of the airway | m |
| \(A\) | Cross-sectional area | m² |
| \(X\) | Sum of shock-loss factors (bends, obstructions) | - |
| \(Q\) | Air flow | m³/s |
| \(\rho\) | Air density | kg/m³ |
| \(R\) | Friction resistance (N·s²/m⁸) | - |
| \(V\) | Air velocity | m/s |
| \(p_f\) | Friction pressure drop | Pa |
| \(p_x\) | Shock pressure drop | Pa |
| \(p\) | Total pressure drop | Pa |
| \(pQ\) | Air power | W |
| \(A_{eq}\) | Equivalent orifice | m² |
| \(R_t\) | Total resistance including shock (N·s²/m⁸) | - |
Method and standards
Atkinson's square law.
Where it is used
- Mine ventilation planning.
- Auxiliary duct and fan selection.
Common mistakes
- Using the area instead of A³.
- Forgetting the density correction at depth.
Assumptions and limits
- Fully turbulent flow; constant density.
References
- Peele (ed.)
- Mining Engineers' Handbook
- 3rd ed. (Wiley, 1941)
- sec. 14
- Mine Ventilation
- arts. 10-13 (friction formula, shock losses, equivalent orifice, resistance factor)
Questions and answers
How do I convert Peele's k values?
Multiply k in lb·min²/ft⁴ by 1.855 × 10⁶ to get K in kg/m³; Peele's 37 × 10⁻¹⁰ becomes 0.0069 kg/m³.
What is the equivalent orifice?
The area of a thin-plate hole passing the same air at the same pressure loss; a large orifice means an easy-to-ventilate mine.
What do the defaults represent?
Peele's 6.2 × 9.2 ft coal-mine butt heading (k = 37 × 10⁻¹⁰), 1 km long, passing 20 m³/s.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.