FireCADCalc

Mine Airway Resistance and Pressure Drop (Atkinson)

Resistance and pressure drop of a mine airway or duct by Atkinson's square law from friction factor, perimeter, length and area, with shock loss and orifice.

Fan and blower

Inputs

Examples: Coal-mine butt heading 6.2 x 9.2 ft (k 37e-10), 1 km, 20 m3/sMetal-mine drift 4 x 4 m, 800 m, two bendsCanvas ventilation duct 600 mm, 300 m (k 25e-10)

K (kg/m³) = 1.855 × 10⁶ × Peele's k (lb·min²/ft⁴)

Results

Peele's friction factors: about 37 × 10⁻¹⁰ for a straight coal-mine heading (K 0.0069), 15 for sheet-metal and 20–25 for canvas ducts; add about 60 % allowance for leakage in real airways. For constant flow, pressure varies with the fifth power of a linear dimension.

Friction resistance (N·s²/m⁸)0.43308
Air velocity3.7742m/s
Friction pressure drop173.23Pa
Shock pressure drop0Pa
Total pressure drop173.23Pa
Air power3.4646kW
Equivalent orifice1.8833m²
Total resistance including shock (N·s²/m⁸)0.43308

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal-mine butt heading 6.2 x 9.2 ft (k 37e-10), 1 km, 20 m3/s. The inputs, in the units selected above:

InputValue
Atkinson friction factor at 1.2 kg/m³0.006865 kg/m³
Perimeter of the airway9.3878 m
Length of the airway1,000.0 m
Cross-sectional area5.2992 m²
Sum of shock-loss factors (bends, obstructions)0 -
Air flow20.000 m³/s
Air density1.2000 kg/m³

Applying the formula below gives:

ResultValue
Friction resistance (N·s²/m⁸)0.43308
Air velocity3.7742 m/s
Friction pressure drop173.23 Pa
Shock pressure drop0 Pa
Total pressure drop173.23 Pa
Air power3.4646 kW
Equivalent orifice1.8833 m²
Total resistance including shock (N·s²/m⁸)0.43308

Open this example in the calculator and change any input.

Formula

\(p = \frac{K O L}{A^3}\frac{\rho}{1.2}Q^2 + X\frac{\rho V^2}{2}, \quad R = \frac{p}{Q^2}, \quad A_{eq} = \frac{Q}{0.625\sqrt{2p/\rho}}\)

Variables

Symbol Meaning SI unit
\(K\) Atkinson friction factor at 1.2 kg/m³ kg/m³
\(O\) Perimeter of the airway m
\(L\) Length of the airway m
\(A\) Cross-sectional area m²
\(X\) Sum of shock-loss factors (bends, obstructions) -
\(Q\) Air flow m³/s
\(\rho\) Air density kg/m³
\(R\) Friction resistance (N·s²/m⁸) -
\(V\) Air velocity m/s
\(p_f\) Friction pressure drop Pa
\(p_x\) Shock pressure drop Pa
\(p\) Total pressure drop Pa
\(pQ\) Air power W
\(A_{eq}\) Equivalent orifice m²
\(R_t\) Total resistance including shock (N·s²/m⁸) -

Method and standards

Atkinson's square law.

Where it is used

  • Mine ventilation planning.
  • Auxiliary duct and fan selection.

Common mistakes

  • Using the area instead of A³.
  • Forgetting the density correction at depth.

Assumptions and limits

  • Fully turbulent flow; constant density.

References

  • Peele (ed.)
  • Mining Engineers' Handbook
  • 3rd ed. (Wiley, 1941)
  • sec. 14
  • Mine Ventilation
  • arts. 10-13 (friction formula, shock losses, equivalent orifice, resistance factor)

Questions and answers

How do I convert Peele's k values?

Multiply k in lb·min²/ft⁴ by 1.855 × 10⁶ to get K in kg/m³; Peele's 37 × 10⁻¹⁰ becomes 0.0069 kg/m³.

What is the equivalent orifice?

The area of a thin-plate hole passing the same air at the same pressure loss; a large orifice means an easy-to-ventilate mine.

What do the defaults represent?

Peele's 6.2 × 9.2 ft coal-mine butt heading (k = 37 × 10⁻¹⁰), 1 km long, passing 20 m³/s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.