Worked example
Example: 250 mm cyclone, 1,500 L/min, 15 % solids by volume. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Cyclone inside diameter | 25.400 cm |
| Inlet diameter (or sqrt(4A/π)) | 6.5000 cm |
| Vortex finder diameter | 9.0000 cm |
| Apex (spigot) diameter | 5.0000 cm |
| Free vortex height (vortex finder to apex) | 90.000 cm |
| Feed slurry flow | 1,500.0 L/min |
| Feed solids by volume | 15.000 % |
| Liquid viscosity | 1.0000 cP |
| Solids density | 2.7000 g/cm³ |
| Hydrodynamic exponent (0.5 laminar) | 0.50000 - |
| Calibration factor for the material (1 if untested) | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Corrected cut size | 39.534 µm |
Open this example in the calculator and change any input.
Formula
\(d_{50c} = \frac{F_1\,39.7 D_c^{0.46} D_i^{0.6} D_o^{1.21}\eta^{0.5} e^{0.06 C_v}}{D_u^{0.71} h^{0.38} Q_f^{0.45}\left(\frac{\rho_s - 1}{1.6}\right)^k}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_c\) | Cyclone inside diameter | m |
| \(D_i\) | Inlet diameter (or sqrt(4A/π)) | m |
| \(D_o\) | Vortex finder diameter | m |
| \(D_u\) | Apex (spigot) diameter | m |
| \(h\) | Free vortex height (vortex finder to apex) | m |
| \(Q_f\) | Feed slurry flow | m³/s |
| \(C_v\) | Feed solids by volume | - |
| \(\eta\) | Liquid viscosity | Pa·s |
| \(\rho_s\) | Solids density | kg/m³ |
| \(k\) | Hydrodynamic exponent (0.5 laminar) | - |
| \(F_1\) | Calibration factor for the material (1 if untested) | - |
| \(d_{50c}\) | Corrected cut size | m |
Method and standards
Plitt's modified cut-size model.
Where it is used
- Selecting cyclone geometry for grinding circuits.
- Estimating the effect of apex and vortex-finder changes.
Common mistakes
- Entering solids by mass instead of by volume.
- Using millimetres instead of centimetres.
Assumptions and limits
- Plitt's database range.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 9
- eq. 9.22 (Plitt, 1976; Flintoff et al., 1987)
Questions and answers
Why does the solids content matter so much?
The cut size grows exponentially with the volume of solids: a dense feed hinders settling and pushes coarser particles to the overflow.
What is F1?
A material factor found by surveying the real cyclone; 1 uses Plitt's database average.
What do the defaults represent?
A 250 mm cyclone with 65 mm inlet, 90 mm vortex finder, 50 mm apex and 900 mm free vortex, fed 1,500 L/min at 15 % solids by volume of 2.7 g/cm³.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.