FireCADCalc

Flotation Recovery against Time: First-Order, Klimpel, Fast/Slow

Batch flotation recovery at a time by the first-order model with maximum recovery, the Klimpel model and the fast/slow two-component model, with time to 95 %.

Inputs

Examples: Wills Appendix VI galena fit, 5 minSlow-floating middlings, 12 minFast copper sulphide, 2 min

Results

Batch (plug-flow) kinetics from a laboratory test; fit the parameters to cumulative recovery against time. For continuous cells use the bank calculator; plant retention is usually the laboratory time times 2–2.5.

Recovery, first-order with R∞93.260%
Recovery, Klimpel (rectangular k distribution)71.685%
Recovery, fast/slow components94.289%
Time to 95 % of R∞ (first-order)1.4979min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Wills Appendix VI galena fit, 5 min. The inputs, in the units selected above:

InputValue
Maximum (infinite-time) recovery97.620 %
Rate constant0.95000 1/min
Flotation time5.0000 min
Fast-floating fraction80.000 %
Fast rate constant1.5000 1/min
Slow rate constant0.15000 1/min

Applying the formula below gives:

ResultValue
Recovery, first-order with R∞96.775 %
Recovery, Klimpel (rectangular k distribution)77.246 %
Recovery, fast/slow components90.508 %
Time to 95 % of R∞ (first-order)3.1534 min

Open this example in the calculator and change any input.

Formula

\(R_1 = R_\infty(1 - e^{-kt}), \quad R_2 = R_\infty\left[1 - \frac{1 - e^{-kt}}{kt}\right], \quad R_3 = \phi_f(1 - e^{-k_f t}) + (1 - \phi_f)(1 - e^{-k_s t})\)

Variables

Symbol Meaning SI unit
\(R_\infty\) Maximum (infinite-time) recovery -
\(k\) Rate constant 1/s
\(t\) Flotation time s
\(\phi_f\) Fast-floating fraction -
\(k_f\) Fast rate constant 1/s
\(k_s\) Slow rate constant 1/s
\(R_1\) Recovery, first-order with R∞ -
\(R_2\) Recovery, Klimpel (rectangular k distribution) -
\(R_3\) Recovery, fast/slow components -
\(t_{95}\) Time to 95 % of R∞ (first-order) s

Method and standards

First-order flotation kinetics.

Where it is used

  • Interpreting laboratory flotation tests.
  • Choosing plant retention time.

Common mistakes

  • Applying batch kinetics to one mixed cell.
  • Fitting k without R∞ when recovery plateaus below 100 %.

Assumptions and limits

  • First-order kinetics.

References

  • Wills and Finch
  • Wills' Mineral Processing Technology
  • 8th ed. (Butterworth-Heinemann, 2016)
  • ch. 12
  • eqs. 12.22-12.26 and 12.51-12.53 (Klimpel, 1980)

Questions and answers

Why are there three models?

The rate constant is really a distribution; Klimpel assumes a uniform spread, the fast/slow model two classes, the simple model one value.

Where do R∞ and k come from?

Fit cumulative recovery from a timed laboratory test; Wills's galena fit gives R∞ 97.62 % and k 0.95 min⁻¹.

What do the defaults represent?

Wills's Appendix VI galena fit (R∞ 97.62 %, k 0.95 min⁻¹) at 5 minutes, with an 80 % fast fraction at 1.5 and 0.15 min⁻¹.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.