FireCADCalc

Flotation Bank Recovery and Selectivity of Two Minerals

Recovery of a valuable mineral and gangue in plug flow, one mixed cell and a bank of N cells from rate constants and retention time, with separation efficiency.

Inputs

Examples: Galena 0.95 /min, gangue 0.08 /min, 12.5 min in 7 cellsCopper rougher, 6 cells, 15 minSingle large cell

Results

Equal, perfectly mixed cells; as N grows the bank approaches plug flow. Gangue recovered by entrainment is not modelled. Separation efficiency is the difference of the two recoveries (Wills eq. 12.43).

Relative rate constant k_A/k_B12.000
Valuable recovery, plug flow100.000%
Gangue recovery, plug flow77.687%
Valuable recovery, one mixed cell94.737%
Gangue recovery, one mixed cell60.000%
Valuable recovery, bank of N cells99.976%
Gangue recovery, bank of N cells73.786%
Separation efficiency of the bank26.190%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Galena 0.95 /min, gangue 0.08 /min, 12.5 min in 7 cells. The inputs, in the units selected above:

InputValue
Rate constant of the valuable mineral0.95000 1/min
Rate constant of the gangue0.080000 1/min
Total bank retention time12.500 min
Number of cells in the bank7.0000 -

Applying the formula below gives:

ResultValue
Relative rate constant k_A/k_B11.875
Valuable recovery, plug flow99.999 %
Gangue recovery, plug flow63.212 %
Valuable recovery, one mixed cell92.233 %
Gangue recovery, one mixed cell50.000 %
Valuable recovery, bank of N cells99.904 %
Gangue recovery, bank of N cells60.730 %
Separation efficiency of the bank39.173 %

Open this example in the calculator and change any input.

Formula

\(R_{plug} = 1 - e^{-kT}, \quad R_1 = \frac{kT}{1 + kT}, \quad R_N = 1 - \left(1 + \frac{kT}{N}\right)^{-N}, \quad SE = R_A - R_B\)

Variables

Symbol Meaning SI unit
\(k_A\) Rate constant of the valuable mineral 1/s
\(k_B\) Rate constant of the gangue 1/s
\(T\) Total bank retention time s
\(N\) Number of cells in the bank -
\(S\) Relative rate constant k_A/k_B -
\(R_{A,plug}\) Valuable recovery, plug flow -
\(R_{B,plug}\) Gangue recovery, plug flow -
\(R_{A,1}\) Valuable recovery, one mixed cell -
\(R_{B,1}\) Gangue recovery, one mixed cell -
\(R_{A,N}\) Valuable recovery, bank of N cells -
\(R_{B,N}\) Gangue recovery, bank of N cells -
\(SE\) Separation efficiency of the bank -

Method and standards

Tanks-in-series flotation kinetics.

Where it is used

  • Choosing the number of cells in a bank.
  • Rougher and scavenger design.

Common mistakes

  • Using total time per cell.
  • Ignoring entrainment of fine gangue.

Assumptions and limits

  • Equal mixed cells; first-order kinetics.

References

  • Wills and Finch
  • Wills' Mineral Processing Technology
  • 8th ed. (Butterworth-Heinemann, 2016)
  • ch. 12
  • eqs. 12.27
  • 12.28
  • 12.43 and 12.46

Questions and answers

Why use several cells instead of one large one?

A single mixed cell lets particles leave immediately; splitting the volume into a bank cuts short-circuiting and approaches plug-flow recovery.

Does a longer bank always help?

It raises valuable recovery but gangue recovery too; separation efficiency passes through a maximum.

What do the defaults represent?

Galena at 0.95 min⁻¹ against gangue at 0.08 min⁻¹ in a 7-cell bank with 12.5 minutes total retention (Wills's Example 12.2 bank).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.