Worked example
Example: Galena 0.95 /min, gangue 0.08 /min, 12.5 min in 7 cells. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rate constant of the valuable mineral | 0.95000 1/min |
| Rate constant of the gangue | 0.080000 1/min |
| Total bank retention time | 12.500 min |
| Number of cells in the bank | 7.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Relative rate constant k_A/k_B | 11.875 |
| Valuable recovery, plug flow | 99.999 % |
| Gangue recovery, plug flow | 63.212 % |
| Valuable recovery, one mixed cell | 92.233 % |
| Gangue recovery, one mixed cell | 50.000 % |
| Valuable recovery, bank of N cells | 99.904 % |
| Gangue recovery, bank of N cells | 60.730 % |
| Separation efficiency of the bank | 39.173 % |
Open this example in the calculator and change any input.
Formula
\(R_{plug} = 1 - e^{-kT}, \quad R_1 = \frac{kT}{1 + kT}, \quad R_N = 1 - \left(1 + \frac{kT}{N}\right)^{-N}, \quad SE = R_A - R_B\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k_A\) | Rate constant of the valuable mineral | 1/s |
| \(k_B\) | Rate constant of the gangue | 1/s |
| \(T\) | Total bank retention time | s |
| \(N\) | Number of cells in the bank | - |
| \(S\) | Relative rate constant k_A/k_B | - |
| \(R_{A,plug}\) | Valuable recovery, plug flow | - |
| \(R_{B,plug}\) | Gangue recovery, plug flow | - |
| \(R_{A,1}\) | Valuable recovery, one mixed cell | - |
| \(R_{B,1}\) | Gangue recovery, one mixed cell | - |
| \(R_{A,N}\) | Valuable recovery, bank of N cells | - |
| \(R_{B,N}\) | Gangue recovery, bank of N cells | - |
| \(SE\) | Separation efficiency of the bank | - |
Method and standards
Tanks-in-series flotation kinetics.
Where it is used
- Choosing the number of cells in a bank.
- Rougher and scavenger design.
Common mistakes
- Using total time per cell.
- Ignoring entrainment of fine gangue.
Assumptions and limits
- Equal mixed cells; first-order kinetics.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 12
- eqs. 12.27
- 12.28
- 12.43 and 12.46
Questions and answers
Why use several cells instead of one large one?
A single mixed cell lets particles leave immediately; splitting the volume into a bank cuts short-circuiting and approaches plug-flow recovery.
Does a longer bank always help?
It raises valuable recovery but gangue recovery too; separation efficiency passes through a maximum.
What do the defaults represent?
Galena at 0.95 min⁻¹ against gangue at 0.08 min⁻¹ in a 7-cell bank with 12.5 minutes total retention (Wills's Example 12.2 bank).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.