FireCADCalc

Rainfall Intensity from an Intensity–Duration–Frequency Equation

Rainfall intensity and depth for a return period and duration from a Sherman-type IDF equation i = KT^a/(t + b)^n with local coefficients.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: Illustrative city, 10-year, 30 min25-year, 60 min

For i in mm/h with t and b in minutes. Coefficients published for in/h: multiply K by 25.4; b must also be in minutes.

Results

Coefficients K, a, b, n are fitted to local rain-gauge records (meteorological department or published regional studies); they are not transferable between cities. Duration for drainage design is the time of concentration.

Rainfall intensity28.318mm/h
Rainfall depth in the duration28.318mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative city, 10-year, 30 min. The inputs, in the units selected above:

InputValue
Coefficient K (mm/h)360.00 -
Return period exponent0.20000 -
Duration offset (min)10.000 -
Duration exponent0.75000 -
Return period (years)10.000 -
Duration30.000 min

Applying the formula below gives:

ResultValue
Rainfall intensity35.872 mm/h
Rainfall depth in the duration17.936 mm

Open this example in the calculator and change any input.

Formula

\(i = \frac{KT^a}{(t + b)^n}\ \ (\mathrm{mm/h},\ t\ \mathrm{in\ min})\)

Variables

Symbol Meaning SI unit
\(K\) Coefficient K (mm/h) -
\(a\) Return period exponent -
\(b\) Duration offset (min) -
\(n\) Duration exponent -
\(T\) Return period (years) -
\(t\) Duration s
\(i\) Rainfall intensity m/s
\(P\) Rainfall depth in the duration m

Method and standards

Sherman IDF equation.

Where it is used

  • Storm drain and roof drainage design.
  • Rational-method peak flows.

Common mistakes

  • Using another region's coefficients.
  • Mixing hours and minutes in t.

Assumptions and limits

  • Point rainfall.
  • K and b are entered as numbers in the equation's own units (i in mm/h, t and b in minutes); they are not converted. Coefficients fitted in inches per hour must be converted first (K × 25.4).

References

  • Sherman-type IDF relation i = KT^a/(t + b)^n (Chow, Maidment and Mays, Applied Hydrology, ch. 14)

Questions and answers

Why does intensity fall with duration?

Short bursts are intense; averaged over longer periods the rate is lower.

Which duration should I use?

The catchment's time of concentration, for the rational method.

What do the defaults represent?

Illustrative coefficients with a 10-year storm of 30 minutes; enter your own region's values.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.