Worked example
Example: Concrete rectangular drain 0.6 m wide, 0.3 m deep, slope 1 in 500. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Channel shape | Rectangular |
| Bottom width (rectangular, trapezoidal) | 0.60000 m |
| Side slope, horizontal per 1 vertical (trapezoidal) | 0 - |
| Pipe diameter (circular) | 600.00 mm |
| Flow depth | 0.30000 m |
| Manning roughness coefficient | 0.013000 - |
| Bed slope | 0.20000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow area | 0.18000 m² |
| Wetted perimeter | 1.2000 m |
| Hydraulic radius | 0.15000 m |
| Mean velocity | 0.97118 m/s |
| Flow | 0.17481 m³/s |
| Froude number | 0.56621 |
Open this example in the calculator and change any input.
Formula
\(v = \frac{1}{n} R^{2/3} S^{1/2}, \quad R = A/P\)
\(Q = v A\)
\(Fr = \frac{v}{\sqrt{g A / T}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{shape}\) | channel shape | - |
| \(b\) | bottom width | m |
| \(z\) | side slope (H per 1 V) | - |
| \(D\) | pipe diameter | m |
| \(y\) | flow depth | m |
| \(n\) | Manning roughness | s/m^(1/3) |
| \(S\) | bed slope | - |
| \(A\) | flow area | m² |
| \(P\) | wetted perimeter | m |
| \(R\) | hydraulic radius | m |
| \(v\) | mean velocity | m/s |
| \(Q\) | flow | m³/s |
| \(Fr\) | Froude number | - |
| \(T\) | top width | m |
| \(g\) | standard gravity | m/s² |
Method and standards
Manning's empirical equation for uniform flow, in SI units. Area, wetted perimeter and top width come from the section geometry; for a part-full pipe the central angle θ = 2 arccos(1 − 2y/D).
Where it is used
- Sizing storm drains and plant trenches.
- Checking cooling water return channels.
- Checking part-full sewer pipes.
Common mistakes
- Using the full-pipe formula for a part-full pipe.
- Using n for a new surface on an old channel.
- Mixing slope in % and m/m.
Assumptions and limits
- Uniform, steady flow; slope and section constant along the reach.
References
- Manning's equation (SI)
Questions and answers
What does a 600 × 300 mm concrete drain at 1 in 500 carry?
About 0.175 m³/s at 0.97 m/s with n 0.013.
Is Manning's n in SI the same as in US units?
Yes, the n values are the same; only the constant differs (1 in SI, 1.49 in US units).
What does the Froude number show?
Below 1 the flow is tranquil (subcritical); above 1 it is rapid and a hydraulic jump can form downstream.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.