Worked example
Example: Illustrative beam, four bars. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steel stress at service load | 240.00 MPa |
| Cover to the centre of the bar nearest the tension face | 50.000 mm |
| Width of the tension zone | 300.00 mm |
| Number of bars | 4.0000 - |
| Overall depth | 600.00 mm |
| Effective depth | 550.00 mm |
| Neutral axis depth at service load (cracked elastic) | 170.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Effective tension area of concrete per bar | 7,500.0 mm² |
| Strain gradient factor (h − x)/(d − x) | 1.1316 |
| Probable maximum crack width | 0.21543 mm |
Open this example in the calculator and change any input.
Formula
\(w = 11\times10^{-6}\,\beta\,f_s\sqrt[3]{d_c A}\ \ \text{(mm, MPa, mm}^2\text{)}, \quad A = \frac{2 d_c b}{n}, \quad \beta = \frac{h - x}{d - x}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(f_s\) | Steel stress at service load | Pa |
| \(d_c\) | Cover to the centre of the bar nearest the tension face | m |
| \(b\) | Width of the tension zone | m |
| \(n\) | Number of bars | - |
| \(h\) | Overall depth | m |
| \(d\) | Effective depth | m |
| \(x\) | Neutral axis depth at service load (cracked elastic) | m |
| \(A\) | Effective tension area of concrete per bar | m² |
| \(\beta\) | Strain gradient factor (h − x)/(d − x) | - |
| \(w\) | Probable maximum crack width | m |
Method and standards
Crack width.
Where it is used
- Serviceability checks of beams and slabs.
- Water-retaining structures.
Common mistakes
- Using the clear cover instead of the cover to the bar centre.
- Taking the ultimate steel stress.
Assumptions and limits
- Flexural cracks at the tension face; one layer of bars.
References
- Gergely–Lutz crack width equation (SI form)
Questions and answers
How do I reduce crack width?
Use more, smaller bars at closer spacing, less cover where allowed, or lower service steel stress.
Where do f_s and x come from?
From a cracked elastic section analysis at service load; the cracked-section calculator gives both.
What do the defaults represent?
An illustrative 300 × 600 mm beam, d = 550 mm, 4 bars with 50 mm to their centres, 240 MPa service stress, neutral axis 170 mm.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gergely and Lutz, Maximum crack width in reinforced concrete flexural members, ACI SP-20 (1968)