Concrete Target Mean Strength and Characteristic Strength from Tests

Target mean strength for a mix design from the characteristic strength and standard deviation, and the characteristic strength achieved by a set of test results.

Inputs

Examples: Illustrative 30 MPa, s = 540 MPa ready-mix, s = 4Poor control 25 MPa

Accepted: 5 to 120 MPa
Accepted: 1 to 15 MPa
Accepted: 1 to 3.5
Accepted: 5 to 150 MPa
Accepted: 0 to 20 MPa

Results

f_t = f_ck + k·s; from tests f_c,k = mean − k·s_m, assuming normally distributed results. Codes add acceptance rules on individual results and set minimum margins when few results exist.

Target mean strength34.900MPa
Characteristic strength from tests18.275MPa
Margin over requirement-6.7250MPa
Expected share below f_ck from the tests26.915%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 30 MPa, s = 5. The inputs, in the units selected above:

InputValue
Characteristic strength required30.000 MPa
Assumed standard deviation5.0000 MPa
Statistical factor (1.65 for 5 % below)1.6500 -
Mean of test results37.500 MPa
Standard deviation of test results4.2000 MPa

Applying the formula below gives:

ResultValue
Target mean strength38.250 MPa
Characteristic strength from tests30.570 MPa
Margin over requirement0.57000 MPa
Expected share below f_ck from the tests3.7073 %

Open this example in the calculator and change any input.

Formula

\(f_t = f_{ck} + ks, \quad f_{c,k} = \bar f - ks_m\)

Variables

Symbol Meaning SI unit
\(f_{ck}\) Characteristic strength required Pa
\(s\) Assumed standard deviation Pa
\(k\) Statistical factor (1.65 for 5 % below) -
\(\bar f\) Mean of test results Pa
\(s_m\) Standard deviation of test results Pa
\(f_t\) Target mean strength Pa
\(f_{c,k}\) Characteristic strength from tests Pa
\(f_{c,k} - f_{ck}\) Margin over requirement Pa
\(p\) Expected share below f_ck from the tests -

Method and standards

Characteristic strength.

Where it is used

  • Concrete mix design.
  • Site quality control and acceptance.

Common mistakes

  • Using too few results for a standard deviation.
  • Confusing cube and cylinder strengths.

Assumptions and limits

  • Normal distribution of strengths.

References

  • Statistical basis of characteristic strength

Questions and answers

Why aim above the required strength?

Concrete strength varies; aiming at the mean plus 1.65 standard deviations keeps about 95 % of results above the characteristic value.

What standard deviation is typical?

About 3.5–6 MPa depending on site control; good ready-mix plants achieve the lower values.

What do the defaults represent?

An illustrative 30 MPa concrete designed with s = 5 MPa, and test results averaging 37.5 MPa with 4.2 MPa standard deviation.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Neville, Properties of Concrete, 5th ed. (Pearson, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.