Worked example
Example: Gas-lifted well with packer, skin 5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wellbore condition | Wellbore full of single-phase fluid (expansion) |
| Volume of fluid in the wellbore | 90.000 bbl |
| Compressibility of the wellbore fluid | 3.0000e-05 1/psi |
| Tubing outside diameter | 2.8750 in |
| Casing inside diameter | 6.1840 in |
| Density of the wellbore liquid | 50.000 lb/ft³ |
| Permeability | 8.0000 mD |
| Net pay thickness | 35.000 ft |
| Viscosity | 1.2000 cP |
| Skin factor | 5.0000 - |
| Porosity | 12.000 % |
| Total compressibility | 1.5000e-05 1/psi |
| Wellbore radius | 0.35400 ft |
Applying the formula below gives:
| Result | Value |
|---|---|
| Storage from fluid expansion | 0.002700 bbl/psi |
| Storage from the moving liquid level | 0.083865 bbl/psi |
| Storage coefficient for the condition chosen | 0.002700 bbl/psi |
| Dimensionless storage | 305.60 |
| Time when the semilog straight line begins | 3.0086 h |
Open this example in the calculator and change any input.
Formula
\(C_{fe} = V_{wb}c_{wb}, \quad C_{fl} = \frac{A_a}{\rho g}, \quad C_D = \frac{C}{2\pi\phi c_thr_w^2}, \quad t > \frac{(200{,}000 + 12{,}000s)C}{kh/\mu}\ (\text{h; field units})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{well}\) | Wellbore condition | - |
| \(V_{wb}\) | Volume of fluid in the wellbore | m³ |
| \(c_{wb}\) | Compressibility of the wellbore fluid | 1/Pa |
| \(OD_t\) | Tubing outside diameter | m |
| \(ID_c\) | Casing inside diameter | m |
| \(\rho\) | Density of the wellbore liquid | kg/m³ |
| \(k\) | Permeability | m² |
| \(h\) | Net pay thickness | m |
| \(\mu\) | Viscosity | Pa·s |
| \(s\) | Skin factor | - |
| \(\phi\) | Porosity | - |
| \(c_t\) | Total compressibility | 1/Pa |
| \(r_w\) | Wellbore radius | m |
| \(C_{fe}\) | Storage from fluid expansion | m³/Pa |
| \(C_{fl}\) | Storage from the moving liquid level | m³/Pa |
| \(C\) | Storage coefficient for the condition chosen | m³/Pa |
| \(C_D\) | Dimensionless storage | - |
| \(t_{end}\) | Time when the semilog straight line begins | s |
Method and standards
Wellbore storage.
Where it is used
- Well test design (test duration).
- Choosing downhole shut-in.
Common mistakes
- Using expansion storage for a well with a free liquid level.
- Ending the test before storage ends.
Assumptions and limits
- Constant storage coefficient.
Questions and answers
Why does storage hide the reservoir response?
After a rate change the wellbore itself supplies or absorbs fluid at first, so the sandface rate lags the surface rate and early pressures reflect the well, not the rock.
How do I see storage in data?
A unit-slope straight line on a log-log plot of Δp against time; the semilog line starts about 1 to 1.5 log cycles after it ends.
What do the defaults represent?
An illustrative case: Gas-lifted well with packer, skin 5. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, wellbore storage equations and Example 6-25