Worked example
Example: Same fits at 5 years. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Duong: rate at day 1 | 50.000 bbl/d |
| Duong intercept a (q/N_p = a t^{−m}) | 3.9747 - |
| Duong slope m | 1.4550 - |
| LGM: ultimate recovery (carrying capacity) | 800,000 bbl |
| LGM constant a (days^n) | 221.25 - |
| LGM exponent n | 1.0980 - |
| Time on production | 1,826.0 d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Rate (Duong) | 4.1960 bbl/d |
| Cumulative production (Duong) | 58,751 bbl |
| Rate (logistic growth) | 24.942 bbl/d |
| Cumulative production (logistic growth) | 756,112 bbl |
| Instantaneous decline rate (LGM), per day | 0.001083 |
| Instantaneous b-factor (LGM) | 0.47371 |
Open this example in the calculator and change any input.
Formula
\(q = q_1t^{-m}\exp\left[\frac{a}{1 - m}(t^{1-m} - 1)\right], \quad N_p = \frac{q_1}{a}\exp\left[\frac{a}{1 - m}(t^{1-m} - 1)\right], \quad N_p = \frac{Kt^n}{a + t^n}, \quad q = \frac{Kna\,t^{n-1}}{(a + t^n)^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q_1\) | Duong: rate at day 1 | m³/s |
| \(a\) | Duong intercept a (q/N_p = a t^{−m}) | - |
| \(m\) | Duong slope m | - |
| \(K\) | LGM: ultimate recovery (carrying capacity) | m³ |
| \(a_{LGM}\) | LGM constant a (days^n) | - |
| \(n\) | LGM exponent n | - |
| \(t\) | Time on production | s |
| \(q_{Duong}\) | Rate (Duong) | m³/s |
| \(N_{p,Duong}\) | Cumulative production (Duong) | m³ |
| \(q_{LGM}\) | Rate (logistic growth) | m³/s |
| \(N_{p,LGM}\) | Cumulative production (logistic growth) | m³ |
| \(D_t\) | Instantaneous decline rate (LGM), per day | - |
| \(b_t\) | Instantaneous b-factor (LGM) | - |
Method and standards
Duong and logistic growth decline models (time in days).
Where it is used
- Shale and tight well forecasts.
- EUR estimates for reserves.
Common mistakes
- Fitting through early flow-back data.
- Mixing time in months with constants fitted in days.
Assumptions and limits
- Constant operating conditions; transient linear flow.
Questions and answers
Why not Arps for shale wells?
Shale wells stay in transient linear flow for years, giving Arps b-factors above 1 that predict unbounded recovery; Duong and the LGM are built for that flow regime.
What is K in the logistic growth model?
The carrying capacity: the cumulative production the well approaches as time goes to infinity, i.e. its EUR.
What do the defaults represent?
An illustrative case: Same fits at 5 years. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 18, eqs. 18-11 and 18-12, the logistic growth model and Examples 18-6 and 18-8 (Duong, 2011; Clark et al., 2011)