Worked example
Example: Acidised well, zone 3 ft at 5 times k. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Formation permeability | 25.000 mD |
| Permeability of the altered zone | 125.00 mD |
| Radius of the altered zone | 3.0000 ft |
| Wellbore radius | 0.35400 ft |
| Oil rate (stock tank) | 450.00 bbl/d |
| Oil viscosity | 0.80000 cP |
| Oil formation volume factor | 1.3000 - |
| Net pay thickness | 40.000 ft |
| Average reservoir pressure | 2,800.0 psi |
| Flowing bottom-hole pressure | 2,100.0 psi |
Applying the formula below gives:
| Result | Value |
|---|---|
| Skin factor | -1.7097 |
| Pressure drop across the skin | -112.98 psi |
| Apparent wellbore radius | 1.9566 ft |
| Flow efficiency | 116.14 % |
| Damage ratio | 0.86103 |
| Bottom-hole pressure for the same rate without skin | 1,987.0 psi |
Open this example in the calculator and change any input.
Formula
\(s = \left(\frac{k}{k_{skin}} - 1\right)\ln\frac{r_{skin}}{r_w}, \quad \Delta p_{skin} = \frac{q_oB_o\mu_o}{2\pi kh}s, \quad r_{wa} = r_we^{-s}, \quad FE = \frac{\bar p - p_{wf} - \Delta p_{skin}}{\bar p - p_{wf}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k\) | Formation permeability | m² |
| \(k_{skin}\) | Permeability of the altered zone | m² |
| \(r_{skin}\) | Radius of the altered zone | m |
| \(r_w\) | Wellbore radius | m |
| \(q_o\) | Oil rate (stock tank) | m³/s |
| \(\mu_o\) | Oil viscosity | Pa·s |
| \(B_o\) | Oil formation volume factor | - |
| \(h\) | Net pay thickness | m |
| \(\bar p\) | Average reservoir pressure | Pa |
| \(p_{wf}\) | Flowing bottom-hole pressure | Pa |
| \(s\) | Skin factor | - |
| \(\Delta p_{skin}\) | Pressure drop across the skin | Pa |
| \(r_{wa}\) | Apparent wellbore radius | m |
| \(FE\) | Flow efficiency | - |
| \(DR\) | Damage ratio | - |
| \(p_{wf,ideal}\) | Bottom-hole pressure for the same rate without skin | Pa |
Method and standards
Hawkins steady-state skin.
Where it is used
- Deciding on a stimulation job.
- Interpreting well tests.
Common mistakes
- Applying a test-derived skin to a different completion.
- Mixing total and mechanical skin.
Assumptions and limits
- Uniform altered zone; Darcy flow.
Questions and answers
What does a skin of 5 mean?
The damaged zone adds as much pressure drop as an extra 5/ln(r_e/r_w) of the whole radial flow; in a typical well that halves the flow efficiency.
Can skin be negative?
Yes. Acidising or fracturing raises the near-well permeability; −3 to −5 is common after a good fracture.
What do the defaults represent?
An illustrative case: Acidised well, zone 3 ft at 5 times k. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-141 to 6-151 and Example 6-19