FireCADCalc

Water Influx from a Pot Aquifer

Cumulative water influx from a small (pot) aquifer for a pressure drop at the oil–water contact, from its size, porosity, compressibilities and encroachment angle.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Full-circle aquifer, 500 psi dropFault block, 120 degree edge water

Accepted: 32.808 to 328,080 ft
Accepted: 32.808 to 328,080 ft
Accepted: 0.32808 to 1,640.4 ft
Accepted: 1 to 50 %
Accepted: 0 to 0.0068948 1/psi
Accepted: 0 to 0.0068948 1/psi
Accepted: 0.57296 to 360 °
Accepted: 0 to 14,504 psi

Results

Only for aquifers comparable in size to the reservoir: the pressure drop is felt instantly through the whole aquifer. Larger aquifers respond with a time lag and need an unsteady model (van Everdingen–Hurst, Fetkovich).

Initial water in the aquifer246.20MMbbl
Fraction of the circle open to the aquifer100.00%
Cumulative water influx923,244bbl

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Full-circle aquifer, 500 psi drop. The inputs, in the units selected above:

InputValue
Outer radius of the aquifer8,000.0 ft
Radius of the reservoir3,000.0 ft
Aquifer thickness40.000 ft
Aquifer porosity20.000 %
Water compressibility3.5000e-06 1/psi
Rock (pore) compressibility4.0000e-06 1/psi
Encroachment angle360.00 °
Pressure drop at the oil–water contact500.00 psi

Applying the formula below gives:

ResultValue
Initial water in the aquifer246.20 MMbbl
Fraction of the circle open to the aquifer100.00 %
Cumulative water influx923,244 bbl

Open this example in the calculator and change any input.

Formula

\(W_i = \pi(r_a^2 - r_e^2)h\phi, \quad W_e = (c_w + c_f)W_if\,(p_i - p), \quad f = \frac{\theta}{360^\circ}\)

Variables

Symbol Meaning SI unit
\(r_a\) Outer radius of the aquifer m
\(r_e\) Radius of the reservoir m
\(h\) Aquifer thickness m
\(\phi\) Aquifer porosity -
\(c_w\) Water compressibility 1/Pa
\(c_f\) Rock (pore) compressibility 1/Pa
\(\theta\) Encroachment angle rad
\(p_i - p\) Pressure drop at the oil–water contact Pa
\(W_i\) Initial water in the aquifer m³
\(f\) Fraction of the circle open to the aquifer -
\(W_e\) Cumulative water influx m³

Method and standards

Pot aquifer (compressibility) model.

Where it is used

  • Material-balance studies of water-drive reservoirs.
  • Screening aquifer support.

Common mistakes

  • Using it for a large aquifer.
  • Using the reservoir instead of the aquifer porosity.

Assumptions and limits

  • Instant pressure equalisation in the aquifer.

Questions and answers

When is the pot model enough?

When the aquifer is not much larger than the reservoir, so pressure equalises quickly through it.

Why include rock compressibility?

Both the water expanding and the pores shrinking push water into the reservoir; for consolidated rock the two are similar in size.

What do the defaults represent?

An illustrative case: Full-circle aquifer, 500 psi drop. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 10, eqs. 10-4 to 10-7 and Example 10-2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.