FireCADCalc

Klinkenberg Correction of Air Permeability

Liquid-equivalent (absolute) permeability from a single air permeability measurement at a mean pressure by the Jones–Klinkenberg relation, with slip factor.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Tight core 0.8 mD at 30 psiaGood core 450 mD at 15 psia

Accepted: 0.00010132 to 10,132 mD
Accepted: 1.4504 to 1,450.4 psi

Results

Gas slips along pore walls, so air permeability exceeds liquid permeability, most of all in tight rock and at low mean pressure: k_g = k_L(1 + b/p_m). With several measurements, plot k_g against 1/p_m and extrapolate to 1/p_m = 0 instead.

Absolute (liquid-equivalent) permeability0.62904mD
Klinkenberg slip factor8.1531psi
Gas to liquid permeability ratio1.2718

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Tight core 0.8 mD at 30 psia. The inputs, in the units selected above:

InputValue
Air (gas) permeability measured0.80000 mD
Mean pressure of the measurement (absolute)30.000 psi

Applying the formula below gives:

ResultValue
Absolute (liquid-equivalent) permeability0.62904 mD
Klinkenberg slip factor8.1531 psi
Gas to liquid permeability ratio1.2718

Open this example in the calculator and change any input.

Formula

\(k_g = k_L\left(1 + \frac{b}{p_m}\right), \quad b = 6.9k_L^{-0.36}\ \Rightarrow\ 6.9k_L^{0.64} + p_mk_L - p_mk_g = 0\ \ (\text{mD, psi})\)

Variables

Symbol Meaning SI unit
\(k_g\) Air (gas) permeability measured m²
\(p_m\) Mean pressure of the measurement (absolute) Pa
\(k_L\) Absolute (liquid-equivalent) permeability m²
\(b\) Klinkenberg slip factor Pa
\(k_g/k_L\) Gas to liquid permeability ratio -

Method and standards

Klinkenberg gas slippage with Jones's slip factor.

Where it is used

  • Core analysis reports.
  • Tight gas and shale permeability.

Common mistakes

  • Using gauge mean pressure.
  • Applying to brine permeability.

Assumptions and limits

  • Single-point estimate; Jones correlation.

Questions and answers

Why is the correction larger in tight rock?

The slip factor rises as permeability falls (b ∝ k^−0.36); in sub-millidarcy rock air permeability can be several times the liquid value.

Why does mean pressure matter?

Gas slip depends on the mean free path, which shrinks as pressure rises; at reservoir pressure the effect nearly vanishes.

What do the defaults represent?

An illustrative case: Tight core 0.8 mD at 30 psia. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 4, eqs. 4-45 to 4-48 and Example 4-10 (Jones)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.