FireCADCalc

Well Interference by Superposition (Ei Solution)

Flowing pressure at a well including the pressure drop caused by up to two neighbouring producing wells, by superposition of line-source solutions.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Same wells with the stated skin -0.5 after 10 daysInfill well 660 ft from two producers, 30 days

Accepted: 0 to 543,440 bbl/d
Accepted: -6 to 50
Accepted: 0.098425 to 1.6404 ft
Accepted: 0 to 543,440 bbl/d
Accepted: 3.2808 to 328,080 ft
Accepted: 0 to 543,440 bbl/d
Accepted: 3.2808 to 328,080 ft
Accepted: 1 to 3
Accepted: 0.01 to 1,000 cP
Accepted: 0.00010132 to 101,320 mD
Accepted: 0.32808 to 1,640.4 ft
Accepted: 1 to 50 %
Accepted: 6.895E-8 to 0.0068948 1/psi
Accepted: 14.504 to 14,504 psi
Accepted: 0.00027778 to 277,780 h

Results

Infinite-acting reservoir, all wells starting together at constant rates. The skin applies only to the well where the pressure is calculated. Set a rate to zero to leave a neighbour out.

Drop from the well's own production329.03psi
Drop caused by neighbour 263.415psi
Drop caused by neighbour 339.396psi
Flowing pressure at the well4,068.2psi

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same wells with the stated skin -0.5 after 10 days. The inputs, in the units selected above:

InputValue
Rate of the well itself100.00 bbl/d
Skin factor of the well-0.50000 -
Wellbore radius0.25000 ft
Rate of neighbour 2160.00 bbl/d
Distance to neighbour 2400.00 ft
Rate of neighbour 3200.00 bbl/d
Distance to neighbour 3700.00 ft
Oil formation volume factor1.2000 -
Oil viscosity2.0000 cP
Permeability40.000 mD
Net pay thickness20.000 ft
Porosity15.000 %
Total compressibility2.0000e-05 1/psi
Initial reservoir pressure4,500.0 psi
Time since all wells started240.00 h

Applying the formula below gives:

ResultValue
Drop from the well's own production329.03 psi
Drop caused by neighbour 263.415 psi
Drop caused by neighbour 339.396 psi
Flowing pressure at the well4,068.2 psi

Open this example in the calculator and change any input.

Formula

\(p_i - p_{wf} = \frac{Q_1B\mu}{4\pi kh}\left[E_1\!\left(\frac{\phi\mu c_tr_w^2}{4kt}\right) + 2s\right] + \sum_j\frac{Q_jB\mu}{4\pi kh}E_1\!\left(\frac{\phi\mu c_tr_j^2}{4kt}\right)\)

Variables

Symbol Meaning SI unit
\(Q_1\) Rate of the well itself m³/s
\(s\) Skin factor of the well -
\(r_w\) Wellbore radius m
\(Q_2\) Rate of neighbour 2 m³/s
\(r_2\) Distance to neighbour 2 m
\(Q_3\) Rate of neighbour 3 m³/s
\(r_3\) Distance to neighbour 3 m
\(B_o\) Oil formation volume factor -
\(\mu_o\) Oil viscosity Pa·s
\(k\) Permeability m²
\(h\) Net pay thickness m
\(\phi\) Porosity -
\(c_t\) Total compressibility 1/Pa
\(p_i\) Initial reservoir pressure Pa
\(t\) Time since all wells started s
\(\Delta p_1\) Drop from the well's own production Pa
\(\Delta p_2\) Drop caused by neighbour 2 Pa
\(\Delta p_3\) Drop caused by neighbour 3 Pa
\(p_{wf}\) Flowing pressure at the well Pa

Method and standards

Superposition of line-source solutions in space.

Where it is used

  • Interference test design.
  • Infill drilling and well spacing.

Common mistakes

  • Using the log approximation for distant wells.
  • Applying the skin to the offset wells.

Assumptions and limits

  • Infinite-acting homogeneous reservoir; constant rates from t = 0.

Questions and answers

Why are offset well effects small early on?

The pressure disturbance from a neighbour takes time to arrive: its Ei argument is large until t ≈ φμc_t r²/k.

What do the defaults represent?

An illustrative case: Same wells with the stated skin -0.5 after 10 days. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, superposition in space and Example 6-21

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.