FireCADCalc

Gas Well Non-Darcy (Turbulence) Coefficient and Apparent Skin

Turbulence parameter, non-Darcy flow coefficient and rate-dependent skin of a gas well, giving the apparent skin s' = s + DQ (Hawkins and Jones).

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Tight gas well, 2 mD, 3 MMscf/dHigh-rate gas well, 150 mD, 45 MMscf/d

Accepted: 0.00010132 to 101,320 mD
Accepted: 1.013E-5 to 101,320 mD
Accepted: 0.098425 to 98.425 ft
Accepted: 0.098425 to 1.6404 ft
Accepted: 1 to 50 %
Accepted: -9.67 to 440.33 °F
Accepted: 0.55 to 1.5
Accepted: 0.001 to 1 cP
Accepted: 0.32808 to 1,640.4 ft
Accepted: 0 to 322,490 Mscf/d

Results

Turbulence near a gas well acts like an extra skin that grows with rate. Multi-rate tests separate s and D by plotting apparent skin against rate. Jones's β correlation is a rough estimate; measured values vary by an order of magnitude.

Mechanical skin (Hawkins)2.4142
Turbulence parameter2.5882e+101/ft
Non-Darcy flow coefficient, psi²/cp/(Mscf/d)²1.8602
Inertial flow factor, per Mscf/d2.3085e-04
Rate-dependent skin0.69255
Apparent skin s + DQ3.1067

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Tight gas well, 2 mD, 3 MMscf/d. The inputs, in the units selected above:

InputValue
Formation permeability2.0000 mD
Permeability of the damaged zone0.80000 mD
Radius of the damaged zone1.5000 ft
Wellbore radius0.30000 ft
Porosity8.0000 %
Reservoir temperature220.33 °F
Gas gravity (air = 1)0.65000 -
Gas viscosity at the bottom-hole pressure0.018000 cP
Net pay thickness60.000 ft
Gas rate3,000.0 Mscf/d

Applying the formula below gives:

ResultValue
Mechanical skin (Hawkins)2.4142
Turbulence parameter2.5882e+10 1/ft
Non-Darcy flow coefficient, psi²/cp/(Mscf/d)²1.8602
Inertial flow factor, per Mscf/d2.3085e-04
Rate-dependent skin0.69255
Apparent skin s + DQ3.1067

Open this example in the calculator and change any input.

Formula

\(\beta = 1.88\times10^{10}k^{-1.47}\phi^{-0.53}, \quad F = 3.161\times10^{-12}\frac{\beta T\gamma_g}{\mu_{gw}h^2r_w}, \quad D = \frac{Fkh}{1422T}, \quad s' = s + DQ_g\)

Variables

Symbol Meaning SI unit
\(k\) Formation permeability m²
\(k_{skin}\) Permeability of the damaged zone m²
\(r_{skin}\) Radius of the damaged zone m
\(r_w\) Wellbore radius m
\(\phi\) Porosity -
\(T\) Reservoir temperature K
\(\gamma_g\) Gas gravity (air = 1) -
\(\mu_{gw}\) Gas viscosity at the bottom-hole pressure Pa·s
\(h\) Net pay thickness m
\(Q_g\) Gas rate Nm³/s
\(s\) Mechanical skin (Hawkins) -
\(\beta\) Turbulence parameter 1/m
\(F\) Non-Darcy flow coefficient, psi²/cp/(Mscf/d)² -
\(D\) Inertial flow factor, per Mscf/d -
\(DQ_g\) Rate-dependent skin -
\(s'\) Apparent skin s + DQ -

Method and standards

Non-Darcy flow coefficient (field units: ft, md, °R, cP, Mscf/d).

Where it is used

  • Gas well test interpretation.
  • Completion design for high-rate gas wells.

Common mistakes

  • Treating s' as mechanical damage.
  • Using μ at reservoir instead of bottom-hole pressure.

Assumptions and limits

  • Radial flow; Jones β correlation.

Questions and answers

Why is non-Darcy flow mostly a gas well problem?

Gas velocities near the wellbore are high enough for inertial losses; oil wells rarely reach them.

How do I reduce the turbulent skin?

Lower the velocity near the well: more perforations, larger hole, a fracture, or removing damage that concentrates flow.

What do the defaults represent?

An illustrative case: Tight gas well, 2 mD, 3 MMscf/d. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-153 to 6-161 and Example 6-20 (Wattenbarger and Ramey, 1968; Jones, 1987)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.