FireCADCalc

Fetkovich Aquifer Water Influx over Time Steps

Cumulative water influx from a finite radial aquifer by Fetkovich's method over up to four equal time steps of falling reservoir boundary pressure.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Full-circle aquifer, constant-pressure edge, two half-year stepsSmall closed aquifer, one step

Accepted: 32.808 to 328,080 ft
Accepted: 32.808 to 3,280,800 ft
Accepted: 0.32808 to 3,280.8 ft
Accepted: 1 to 50 %
Accepted: 6.895E-8 to 0.0068948 1/psi
Accepted: 0.57296 to 360 °
Accepted: 0.00010132 to 101,320 mD
Accepted: 0.01 to 10 cP
Accepted: 14.504 to 14,504 psi
Accepted: 1 to 115,740 d
Accepted: 14.504 to 14,504 psi
Accepted: 0 to 14,504 psi
Accepted: 0 to 14,504 psi
Accepted: 0 to 14,504 psi

Results

Fetkovich treats the aquifer as a tank feeding the reservoir through a productivity index, so no superposition tables are needed. Each step uses the mean boundary pressure over the step and the aquifer pressure left by the previous one. Unused steps repeat the last cumulative value.

Initial water in the aquifer190.36MMbbl
Maximum possible influx1.1041MMbbl
Aquifer productivity index319.41bbl/(d·psi)
Cumulative influx after step 10.057107MMbbl
After step 20.057107MMbbl
After step 30.057107MMbbl
After step 40.057107MMbbl

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Full-circle aquifer, constant-pressure edge, two half-year steps. The inputs, in the units selected above:

InputValue
Reservoir radius5,000.0 ft
Aquifer outer radius30,000 ft
Aquifer thickness60.000 ft
Aquifer porosity20.000 %
Aquifer total compressibility (c_w + c_f)6.0000e-06 1/psi
Encroachment angle360.00 °
Aquifer permeability80.000 mD
Water viscosity0.50000 cP
Aquifer outer boundaryConstant pressure
Initial pressure3,500.0 psi
Length of each time step182.50 d
Boundary pressure at the end of step 13,400.0 psi
At the end of step 2 (0 if unused)3,280.0 psi
At the end of step 3 (0 if unused)0 psi
At the end of step 4 (0 if unused)0 psi

Applying the formula below gives:

ResultValue
Initial water in the aquifer5,875.2 MMbbl
Maximum possible influx123.38 MMbbl
Aquifer productivity index37.944 bbl/(d·psi)
Cumulative influx after step 10.31435 MMbbl
After step 21.2642 MMbbl
After step 31.2642 MMbbl
After step 41.2642 MMbbl

Open this example in the calculator and change any input.

Formula

\(W_{e,max} = c_tW_ip_if, \quad J = \frac{2\pi khf}{\mu_w[\ln(r_a/r_e) - 0.75]}, \quad \Delta W_{e,n} = \frac{W_{e,max}}{p_i}(\bar p_{a,n-1} - \bar p_{r,n})\left(1 - e^{-Jp_i\Delta t/W_{e,max}}\right)\)

Variables

Symbol Meaning SI unit
\(r_e\) Reservoir radius m
\(r_a\) Aquifer outer radius m
\(h\) Aquifer thickness m
\(\phi\) Aquifer porosity -
\(c_t\) Aquifer total compressibility (c_w + c_f) 1/Pa
\(\theta\) Encroachment angle rad
\(k\) Aquifer permeability m²
\(\mu_w\) Water viscosity Pa·s
\(\text{outer boundary}\) Aquifer outer boundary -
\(p_i\) Initial pressure Pa
\(\Delta t\) Length of each time step s
\(p_1\) Boundary pressure at the end of step 1 Pa
\(p_2\) At the end of step 2 (0 if unused) Pa
\(p_3\) At the end of step 3 (0 if unused) Pa
\(p_4\) At the end of step 4 (0 if unused) Pa
\(W_i\) Initial water in the aquifer m³
\(W_{e,max}\) Maximum possible influx m³
\(J\) Aquifer productivity index m³/(s·Pa)
\(W_{e,1}\) Cumulative influx after step 1 m³
\(W_{e,2}\) After step 2 m³
\(W_{e,3}\) After step 3 m³
\(W_{e,4}\) After step 4 m³

Method and standards

Fetkovich pseudo-steady aquifer.

Where it is used

  • Water-drive material balance.
  • History matching aquifer strength.

Common mistakes

  • Using it for infinite aquifers without the time-dependent J.
  • Using end-of-step instead of average boundary pressure.

Assumptions and limits

  • Radial aquifer; pseudo-steady aquifer flow.

Questions and answers

How is Fetkovich's method different from van Everdingen–Hurst?

It replaces the unsteady superposition with a pseudo-steady aquifer tank, giving nearly the same answers for finite aquifers with far less arithmetic.

What limits the influx?

The maximum possible influx W_e,max = c_tW_ip_if is reached only if the aquifer pressure fell to zero; the productivity index sets how fast it is approached.

What do the defaults represent?

An illustrative case: Full-circle aquifer, constant-pressure edge, two half-year steps. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 10, eqs. 10-37 to 10-46 and Example 10-10 (after Dake)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.