Worked example
Example: Full-circle aquifer, constant-pressure edge, two half-year steps. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reservoir radius | 5,000.0 ft |
| Aquifer outer radius | 30,000 ft |
| Aquifer thickness | 60.000 ft |
| Aquifer porosity | 20.000 % |
| Aquifer total compressibility (c_w + c_f) | 6.0000e-06 1/psi |
| Encroachment angle | 360.00 ° |
| Aquifer permeability | 80.000 mD |
| Water viscosity | 0.50000 cP |
| Aquifer outer boundary | Constant pressure |
| Initial pressure | 3,500.0 psi |
| Length of each time step | 182.50 d |
| Boundary pressure at the end of step 1 | 3,400.0 psi |
| At the end of step 2 (0 if unused) | 3,280.0 psi |
| At the end of step 3 (0 if unused) | 0 psi |
| At the end of step 4 (0 if unused) | 0 psi |
Applying the formula below gives:
| Result | Value |
|---|---|
| Initial water in the aquifer | 5,875.2 MMbbl |
| Maximum possible influx | 123.38 MMbbl |
| Aquifer productivity index | 37.944 bbl/(d·psi) |
| Cumulative influx after step 1 | 0.31435 MMbbl |
| After step 2 | 1.2642 MMbbl |
| After step 3 | 1.2642 MMbbl |
| After step 4 | 1.2642 MMbbl |
Open this example in the calculator and change any input.
Formula
\(W_{e,max} = c_tW_ip_if, \quad J = \frac{2\pi khf}{\mu_w[\ln(r_a/r_e) - 0.75]}, \quad \Delta W_{e,n} = \frac{W_{e,max}}{p_i}(\bar p_{a,n-1} - \bar p_{r,n})\left(1 - e^{-Jp_i\Delta t/W_{e,max}}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(r_e\) | Reservoir radius | m |
| \(r_a\) | Aquifer outer radius | m |
| \(h\) | Aquifer thickness | m |
| \(\phi\) | Aquifer porosity | - |
| \(c_t\) | Aquifer total compressibility (c_w + c_f) | 1/Pa |
| \(\theta\) | Encroachment angle | rad |
| \(k\) | Aquifer permeability | m² |
| \(\mu_w\) | Water viscosity | Pa·s |
| \(\text{outer boundary}\) | Aquifer outer boundary | - |
| \(p_i\) | Initial pressure | Pa |
| \(\Delta t\) | Length of each time step | s |
| \(p_1\) | Boundary pressure at the end of step 1 | Pa |
| \(p_2\) | At the end of step 2 (0 if unused) | Pa |
| \(p_3\) | At the end of step 3 (0 if unused) | Pa |
| \(p_4\) | At the end of step 4 (0 if unused) | Pa |
| \(W_i\) | Initial water in the aquifer | m³ |
| \(W_{e,max}\) | Maximum possible influx | m³ |
| \(J\) | Aquifer productivity index | m³/(s·Pa) |
| \(W_{e,1}\) | Cumulative influx after step 1 | m³ |
| \(W_{e,2}\) | After step 2 | m³ |
| \(W_{e,3}\) | After step 3 | m³ |
| \(W_{e,4}\) | After step 4 | m³ |
Method and standards
Fetkovich pseudo-steady aquifer.
Where it is used
- Water-drive material balance.
- History matching aquifer strength.
Common mistakes
- Using it for infinite aquifers without the time-dependent J.
- Using end-of-step instead of average boundary pressure.
Assumptions and limits
- Radial aquifer; pseudo-steady aquifer flow.
Questions and answers
How is Fetkovich's method different from van Everdingen–Hurst?
It replaces the unsteady superposition with a pseudo-steady aquifer tank, giving nearly the same answers for finite aquifers with far less arithmetic.
What limits the influx?
The maximum possible influx W_e,max = c_tW_ip_if is reached only if the aquifer pressure fell to zero; the productivity index sets how fast it is approached.
What do the defaults represent?
An illustrative case: Full-circle aquifer, constant-pressure edge, two half-year steps. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 10, eqs. 10-37 to 10-46 and Example 10-10 (after Dake)