FireCADCalc

Dykstra–Parsons Permeability Variation and Lorenz Coefficient

Dykstra–Parsons permeability variation V from the median and 84.1 percentile permeabilities, and the matching Lorenz coefficient of heterogeneity.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Uniform reservoir, V = 0.2Very heterogeneous, V = 0.85

Accepted: 0.00010132 to 101,320 mD
Accepted: 1.013E-5 to 101,320 mD

Results

V = 0 is a uniform reservoir and V → 1 is extremely heterogeneous; most reservoirs lie between 0.5 and 0.9. Read k₅₀ and k₈₄.₁ from a log-probability plot of the core permeabilities ranked from highest to lowest.

Dykstra–Parsons permeability variation0.85000
Lorenz coefficient0.83435

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Uniform reservoir, V = 0.2. The inputs, in the units selected above:

InputValue
Median permeability (50 % of thickness has more)100.00 mD
Permeability exceeded by 84.1 % of the thickness80.000 mD

Applying the formula below gives:

ResultValue
Dykstra–Parsons permeability variation0.20000
Lorenz coefficient0.11917

Open this example in the calculator and change any input.

Formula

\(V = \frac{k_{50} - k_{84.1}}{k_{50}}, \quad L = 0.0116356 + 0.339794V + 1.066405V^2 - 0.3852407V^3\)

Variables

Symbol Meaning SI unit
\(k_{50}\) Median permeability (50 % of thickness has more) m²
\(k_{84.1}\) Permeability exceeded by 84.1 % of the thickness m²
\(V\) Dykstra–Parsons permeability variation -
\(L\) Lorenz coefficient -

Method and standards

Dykstra–Parsons and Lorenz heterogeneity measures.

Where it is used

  • Waterflood vertical sweep prediction.
  • Comparing reservoirs.

Common mistakes

  • Ranking permeabilities in ascending order.
  • Mixing core from different layers' flow units.

Assumptions and limits

  • Log-normal permeability distribution.

Questions and answers

Why does heterogeneity matter for waterfloods?

Water races through the best layers; a high V means early breakthrough and poor vertical sweep.

Why use the 84.1 percentile?

For a log-normal distribution it lies one standard deviation below the median, so V measures the spread of ln k.

What do the defaults represent?

An illustrative case: Uniform reservoir, V = 0.2. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 4, eqs. 4-70 and 4-72 and Examples 4-18 to 4-20

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.