Worked example
Example: Uniform reservoir, V = 0.2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Median permeability (50 % of thickness has more) | 100.00 mD |
| Permeability exceeded by 84.1 % of the thickness | 80.000 mD |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dykstra–Parsons permeability variation | 0.20000 |
| Lorenz coefficient | 0.11917 |
Open this example in the calculator and change any input.
Formula
\(V = \frac{k_{50} - k_{84.1}}{k_{50}}, \quad L = 0.0116356 + 0.339794V + 1.066405V^2 - 0.3852407V^3\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k_{50}\) | Median permeability (50 % of thickness has more) | m² |
| \(k_{84.1}\) | Permeability exceeded by 84.1 % of the thickness | m² |
| \(V\) | Dykstra–Parsons permeability variation | - |
| \(L\) | Lorenz coefficient | - |
Method and standards
Dykstra–Parsons and Lorenz heterogeneity measures.
Where it is used
- Waterflood vertical sweep prediction.
- Comparing reservoirs.
Common mistakes
- Ranking permeabilities in ascending order.
- Mixing core from different layers' flow units.
Assumptions and limits
- Log-normal permeability distribution.
Questions and answers
Why does heterogeneity matter for waterfloods?
Water races through the best layers; a high V means early breakthrough and poor vertical sweep.
Why use the 84.1 percentile?
For a log-normal distribution it lies one standard deviation below the median, so V measures the spread of ln k.
What do the defaults represent?
An illustrative case: Uniform reservoir, V = 0.2. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 4, eqs. 4-70 and 4-72 and Examples 4-18 to 4-20