Worked example
Example: Bottom water, 50 ft oil column. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Coning case | Bottom water below (water coning) |
| Effective oil permeability | 93.500 mD |
| Oil viscosity | 0.73000 cP |
| Oil formation volume factor | 1.1000 - |
| Oil density (reservoir) | 47.500 lb/ft³ |
| Water density (reservoir) | 63.760 lb/ft³ |
| Gas density (reservoir) | 5.1000 lb/ft³ |
| Oil column thickness | 50.000 ft |
| Perforated interval | 15.000 ft |
| Drainage radius | 660.00 ft |
| Wellbore radius | 0.25000 ft |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical oil rate | 13.443 bbl/d |
| Effective density difference | 16.260 lb/ft³ |
Open this example in the calculator and change any input.
Formula
\(Q_{oc} = \frac{\pi g k_o\,\Delta\rho\,(h^2 - h_p^2)}{\mu_oB_o\ln(r_e/r_w)}, \quad \Delta\rho_{both} = (\rho_w - \rho_o)\left(\frac{\rho_o - \rho_g}{\rho_w - \rho_g}\right)^2 + (\rho_o - \rho_g)\left(1 - \frac{\rho_o - \rho_g}{\rho_w - \rho_g}\right)^2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{case}\) | Coning case | - |
| \(k_o\) | Effective oil permeability | m² |
| \(\mu_o\) | Oil viscosity | Pa·s |
| \(B_o\) | Oil formation volume factor | - |
| \(\rho_o\) | Oil density (reservoir) | kg/m³ |
| \(\rho_w\) | Water density (reservoir) | kg/m³ |
| \(\rho_g\) | Gas density (reservoir) | kg/m³ |
| \(h\) | Oil column thickness | m |
| \(h_p\) | Perforated interval | m |
| \(r_e\) | Drainage radius | m |
| \(r_w\) | Wellbore radius | m |
| \(Q_{oc}\) | Critical oil rate | m³/s |
| \(\Delta\rho_{eff}\) | Effective density difference | kg/m³ |
Method and standards
Meyer–Garder critical rate.
Where it is used
- Completion design in thin oil columns.
- Setting allowables to delay water or gas breakthrough.
Common mistakes
- Using absolute instead of effective oil permeability.
- Measuring h_p from the wrong contact.
Assumptions and limits
- Homogeneous isotropic reservoir; stable cone.
Questions and answers
Why are critical rates so low?
The cone is held down only by the density difference between the fluids; a few tens of bbl/d of drawdown is enough to overcome it in typical reservoirs.
How do horizontal wells help?
They spread the drawdown along a long section, so the rate per foot stays below the critical value.
What do the defaults represent?
An illustrative case: Bottom water, 50 ft oil column. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 9, eqs. 9-1 to 9-3 and Examples 9-1 to 9-3 (Meyer and Garder; Pirson)