Worked example
Example: Air 20 °C, 1 to 200 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Initial temperature | 20.000 °C |
| Initial pressure (absolute) | 1.0132 bar |
| Final pressure (absolute) | 200.00 bar |
| Ratio of specific heats | 1.4000 - |
| Autoignition temperature of the material at risk | 350.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature after compression | 1,053.9 °C |
| Margin to autoignition | -703.92 K |
Open this example in the calculator and change any input.
Formula
\(T_2 = T_1\left(\frac{p_2}{p_1}\right)^{(\gamma - 1)/\gamma}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | Initial temperature | K |
| \(p_1\) | Initial pressure (absolute) | Pa |
| \(p_2\) | Final pressure (absolute) | Pa |
| \(\gamma\) | Ratio of specific heats | - |
| \(T_{AIT}\) | Autoignition temperature of the material at risk | K |
| \(T_2\) | Temperature after compression | K |
| \(T_{AIT} - T_2\) | Margin to autoignition | K |
Method and standards
Isentropic compression of the trapped gas, the textbook screening form. Oxygen-compatibility assessments (for example ASTM G74-type pneumatic impact tests) often model the rapid filling of a dead end differently, and the numbers differ; use this page as an indicator of the hazard, not as a substitute for those methods.
Where it is used
- Oxygen system design.
- Pneumatic and hydraulic safety reviews.
Common mistakes
- Using gauge pressures.
- Ignoring that seals ignite below metal.
Assumptions and limits
- Ideal gas; no heat loss.
References
- Isentropic compression of an ideal gas (definitions)
Questions and answers
Why can opening an oxygen valve start a fire?
Gas rushing into a dead-ended line is compressed almost adiabatically and can exceed the autoignition temperature of seals or contaminants.
What does 1 to 200 bar give?
Air from 20 °C reaches over 1,000 °C in theory.
Is the real temperature that high?
Heat loss lowers it, but the estimate shows the risk.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.