FireCADCalc

Wellhead Choke Performance: Gilbert, Ros, Baxendell, Achong

Wellhead pressure for liquid rate, gas-liquid ratio and choke size by the Gilbert-type correlations, and the choke size for a target wellhead pressure.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: High-GLR well, 1200 STB/d, 800 scf/STB, 24/64Low-rate well, 150 STB/d, 400 scf/STB, 16/64

Accepted: 0.54344 to 543,440 bbl/d
Accepted: 5.6146 to 28,073 scf/STB
Accepted: 0.03937 to 3.937 in
Accepted: 14.504 to 14,504 psi

Results

Critical (sonic) flow through the choke: the downstream line pressure must be below about half the wellhead pressure, so that flowline changes do not reach the well. The correlations are empirical; Gilbert's is the most widely used.

Wellhead pressure, Gilbert1,137.5psi
Wellhead pressure, Ros1,028.2psi
Wellhead pressure, Baxendell956.19psi
Wellhead pressure, Achong900.60psi
Choke size for the target pressure (Gilbert)0.61251in
That choke size in 64ths of an inch39.201

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: High-GLR well, 1200 STB/d, 800 scf/STB, 24/64. The inputs, in the units selected above:

InputValue
Liquid rate1,200.0 bbl/d
Gas-liquid ratio800.00 scf/STB
Choke bean size0.37500 in
Target wellhead pressure (for sizing)450.00 psi

Applying the formula below gives:

ResultValue
Wellhead pressure, Gilbert1,137.5 psi
Wellhead pressure, Ros1,028.2 psi
Wellhead pressure, Baxendell956.19 psi
Wellhead pressure, Achong900.60 psi
Choke size for the target pressure (Gilbert)0.61251 in
That choke size in 64ths of an inch39.201

Open this example in the calculator and change any input.

Formula

\(p_{wh} = \frac{a_1Q_L(GLR)^{a_2}}{d^{a_3}}; \quad \text{Gilbert } (3.86\times10^{-3}, 0.546, 1.89),\ \text{Ros } (4.26\times10^{-3}, 0.5, 2.0),\ \text{Baxendell } (3.12\times10^{-3}, 0.546, 1.93),\ \text{Achong } (1.54\times10^{-3}, 0.65, 1.88)\)

Variables

Symbol Meaning SI unit
\(Q_L\) Liquid rate m³/s
\(GLR\) Gas-liquid ratio m³/m³
\(d\) Choke bean size m
\(p_{wh,target}\) Target wellhead pressure (for sizing) Pa
\(p_{wh,Gilbert}\) Wellhead pressure, Gilbert Pa
\(p_{wh,Ros}\) Wellhead pressure, Ros Pa
\(p_{wh,Baxendell}\) Wellhead pressure, Baxendell Pa
\(p_{wh,Achong}\) Wellhead pressure, Achong Pa
\(d_{Gilbert}\) Choke size for the target pressure (Gilbert) m
\(d/64\) That choke size in 64ths of an inch -

Method and standards

Gilbert-type critical-flow choke correlations (psi, STB/d, scf/STB, in).

Where it is used

  • Choke selection for new wells.
  • Checking well rates from wellhead pressure.

Common mistakes

  • Applying it in subcritical flow.
  • Entering the choke in 64ths instead of inches.

Assumptions and limits

  • Critical flow through the choke.

Questions and answers

Why does the wellhead pressure scale with rate?

In critical flow the choke behaves like a nozzle: at fixed GLR and size, rate and upstream pressure are proportional.

What is a 32/64 choke?

Choke beans are sized in 64ths of an inch; 32/64 is a half-inch bore.

What do the defaults represent?

An illustrative case: High-GLR well, 1200 STB/d, 800 scf/STB, 24/64. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 7, eq. 7-80, the coefficient table and Example 7-20 (Gilbert, Ros, Baxendell, Achong)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.