FireCADCalc

TEG Regenerator Reboiler Duty

Reboiler duty of a triethylene glycol regenerator from glycol circulation, heating to reboiler temperature, water boiled off, still reflux and heat losses.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative 1.5 m3/h TEG, 50 kg/h waterNo lean/rich exchangerLarge unit 8 m3/h

Accepted: 0.0036 to 180 m³/h
Accepted: 1,000 to 1,200 kg/m³
Accepted: 1.8 to 3.2 kJ/(kg·K)
Accepted: 26.85 to 206.85 °C
Accepted: 146.85 to 206.85 °C
Accepted: 0 to 3,600 kg/h
Accepted: 2,000 to 3,000 kJ/kg
Accepted: 0 to 1
Accepted: 0 to 30 %

Results

Duty = [sensible + vaporisation + reflux]/(1 − losses). The reboiler normally runs near 200–204 °C (above that TEG degrades); a lean/rich exchanger heating the rich glycol is the main lever on duty. Rules of thumb are about 2,000 Btu per US gallon of TEG circulated; check against this result.

Sensible heat62.438kW
Water vaporisation34.444kW
Reflux duty8.6111kW
Reboiler duty117.21kW
Duty per litre of glycol circulated (kJ/L)281.31

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.5 m3/h TEG, 50 kg/h water. The inputs, in the units selected above:

InputValue
Glycol circulation1.5000 m³/h
Rich glycol density1,110.0 kg/m³
Glycol specific heat2.5000 kJ/(kg·K)
Rich glycol temperature to the reboiler150.00 °C
Reboiler temperature204.00 °C
Water removed50.000 kg/h
Heat to vaporise water (incl. desorption)2,480.0 kJ/kg
Reflux ratio (water refluxed per water removed)0.25000 -
Heat losses10.000 %

Applying the formula below gives:

ResultValue
Sensible heat62.438 kW
Water vaporisation34.444 kW
Reflux duty8.6111 kW
Reboiler duty117.21 kW
Duty per litre of glycol circulated (kJ/L)281.31

Open this example in the calculator and change any input.

Formula

\(\dot Q = \frac{\dot V_g\rho c_p(T_r - T_{in}) + \dot m_wh_{fg}(1 + r)}{1 - f_L}\)

Variables

Symbol Meaning SI unit
\(\dot V_g\) Glycol circulation m³/s
\(\rho_g\) Rich glycol density kg/m³
\(c_{p,g}\) Glycol specific heat J/(kg·K)
\(T_{in}\) Rich glycol temperature to the reboiler K
\(T_r\) Reboiler temperature K
\(\dot m_w\) Water removed kg/s
\(h_{fg}\) Heat to vaporise water (incl. desorption) J/kg
\(r\) Reflux ratio (water refluxed per water removed) -
\(f_L\) Heat losses -
\(\dot Q_s\) Sensible heat W
\(\dot Q_v\) Water vaporisation W
\(\dot Q_r\) Reflux duty W
\(\dot Q\) Reboiler duty W
\(\dot Q/\dot V_g\) Duty per litre of glycol circulated (kJ/L) -

Method and standards

Reboiler duty.

Where it is used

  • Dehydration unit design and debottlenecking.
  • Fuel gas use estimates.

Common mistakes

  • Forgetting reflux and losses.
  • Using lean instead of rich glycol flow.

Assumptions and limits

  • Steady state; constant properties.

References

  • Glycol regenerator heat balance

Questions and answers

What reboiler temperature is used?

About 200–204 °C; higher temperatures give leaner glycol but degrade TEG.

How can duty be reduced?

Preheat rich glycol against hot lean glycol and avoid over-circulating.

What do the defaults represent?

An illustrative 1.5 m³/h TEG at 1,110 kg/m³ heated from 150 to 204 °C, removing 50 kg/h of water with 25 % reflux and 10 % losses.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

GPSA Engineering Data Book, 12th ed. (Gas Processors Suppliers Association, 2004), Kohl and Nielsen, Gas Purification, 5th ed. (Gulf, 1997)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.