FireCADCalc

Gas Pipeline Flow: Weymouth, Panhandle, IGT and Others

Gas flow through a pipeline from inlet and outlet pressures by the Weymouth, Panhandle A or B, IGT, Spitzglass, Mueller or Fritzsche equation, with elevation.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas system

Inputs

Examples: IGT, Menon Example 20Panhandle A, 7.471 to 6 MPa (Menon Example 16)Weymouth with a 200 m riseMueller, distribution mainFritzsche, compressed gas headerPanhandle BSpitzglass high pressure

Results

Empirical equations with a pipeline efficiency E in place of roughness; Z is taken at the average pressure (Menon eq. 2.14). Velocities assume Z = 1 at base conditions.

Gas flow at base conditions5,747,142m³/d
Average pressure6,380.5kPa
Equivalent length for elevation24.000km
Gas velocity at the inlet7.3501m/s
Gas velocity at the outlet9.3186m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: IGT, Menon Example 20. The inputs, in the units selected above:

InputValue
Flow equationIGT
Inlet pressure (absolute)7,101.0 kPa
Outlet pressure (absolute)5,601.0 kPa
Pipe inside diameter388.00 mm
Pipe length24.000 km
Inlet elevation0 m
Outlet elevation0 m
Gas gravity (air = 1)0.60000 -
Average gas temperature19.850 °C
Compressibility factor0.90000 -
Pipeline efficiency95.000 %
Gas viscosity (IGT and Mueller only)0.011900 cP
Base temperature14.850 °C
Base pressure101.00 kPa

Applying the formula below gives:

ResultValue
Gas flow at base conditions7,665,328 m³/d
Average pressure6,380.5 kPa
Equivalent length for elevation24.000 km
Gas velocity at the inlet9.7720 m/s
Gas velocity at the outlet12.389 m/s

Open this example in the calculator and change any input.

Formula

\(Q_b = C\,E\left(\frac{T_b}{P_b}\right)^{a}\left(\frac{P_1^2 - e^sP_2^2}{G^{b}T_fL_eZ}\right)^{c}D^{n}\)

\(s = 0.0684\,G\frac{H_2 - H_1}{T_fZ}, \quad L_e = L\frac{e^s - 1}{s}, \quad P_{avg} = \tfrac23\left(P_1 + P_2 - \frac{P_1P_2}{P_1 + P_2}\right)\)

Variables

Symbol Meaning SI unit
\(\text{eq.}\) Flow equation -
\(P_1\) Inlet pressure (absolute) Pa
\(P_2\) Outlet pressure (absolute) Pa
\(D\) Pipe inside diameter m
\(L\) Pipe length m
\(H_1\) Inlet elevation m
\(H_2\) Outlet elevation m
\(G\) Gas gravity (air = 1) -
\(T_f\) Average gas temperature K
\(Z\) Compressibility factor -
\(E\) Pipeline efficiency -
\(\mu\) Gas viscosity (IGT and Mueller only) Pa·s
\(T_b\) Base temperature K
\(P_b\) Base pressure Pa
\(Q_b\) Gas flow at base conditions m³/s
\(P_{avg}\) Average pressure Pa
\(L_e\) Equivalent length for elevation m
\(u_1\) Gas velocity at the inlet m/s
\(u_2\) Gas velocity at the outlet m/s

Method and standards

The constants and exponents are those of Menon's SI forms (Q in m³/day at base conditions, P in kPa, D in mm, L in km, T in K): Weymouth C = 3.7435×10⁻³, n = 2.667; Panhandle A C = 4.5965×10⁻³, a = 1.0788, b = 0.8539, c = 0.5394, n = 2.6182; Panhandle B C = 1.002×10⁻², a = 1.02, b = 0.961, c = 0.51, n = 2.53; IGT C = 1.2822×10⁻³, b = 0.8, c = 0.555, n = 2.667 with μ0.2 (poise) in place of Z; Spitzglass C = 1.0815×10⁻², with (1 + 91.44/D + 0.0012D) beside Z; Mueller (b = 0.7391, c = 0.575, n = 2.725, with μ0.2609 in place of Z) and Fritzsche (b = 0.8587, c = 0.538, n = 2.69, no Z) use Menon's US-unit forms, eqs. 2.69 and 2.71 (C = 85.7368 and 410.1688; SCFD, psia, inch, mile, °R, μ in lb/(ft·s)), because his SI constants for these two do not agree with the US forms (by a factor of about 22 and 1,000). The elevation term e^s is applied to all seven.

Where it is used

  • Checking the capacity of an existing gas line.
  • Comparing the classic equations for a new transmission or plant fuel-gas line.

Common mistakes

  • Entering gauge pressures: all pressures are absolute.
  • Using Panhandle outside its Reynolds number range.
  • Forgetting that Weymouth is conservative and under-predicts flow in large lines.

Assumptions and limits

  • Steady, isothermal flow; constant Z at the average pressure.
  • Single slope between inlet and outlet for the elevation correction.

References

  • Menon
  • Gas Pipeline Hydraulics (CRC Press, 2005)
  • ch. 2
  • eqs. 2.9–2.14
  • 2.29
  • 2.54
  • 2.56
  • 2.60
  • 2.64
  • 2.68
  • 2.69
  • 2.71

Questions and answers

Which equation should I use?

Weymouth is conservative and suits gathering lines; Panhandle A and B suit long transmission lines; IGT, Mueller and Spitzglass suit distribution and fuel-gas piping. The AGA method with roughness is the most general.

What is pipeline efficiency?

A factor of about 0.88–0.95 that matches the empirical equation to measured flows; it stands in for roughness, bends and fittings.

What do the defaults represent?

Menon's Example 20: a DN 400 line, 24 km long, 7,000 to 5,500 kPa gauge, gas gravity 0.6 at 20 °C, by the IGT equation (7.67 million m³/day).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.