Worked example
Example: Mokhatab Example 3-2 (59.1 °F), line at 40 °F. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas pressure (absolute) | 661.37 psi |
| Gas specific gravity (air = 1) | 0.70900 - |
| Lowest line temperature | 4.4444 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydrate formation temperature | 15.047 °C |
| Cooling below the hydrate point (positive = hydrates form) | 10.602 K |
Open this example in the calculator and change any input.
Formula
\(T_h = 13.47\ln P + 34.27\ln SG - 1.675\ln P\ln SG - 20.35\ (\text{°F, psia})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Gas pressure (absolute) | Pa |
| \(SG\) | Gas specific gravity (air = 1) | - |
| \(T_l\) | Lowest line temperature | K |
| \(T_h\) | Hydrate formation temperature | K |
| \(T_h - T_l\) | Cooling below the hydrate point (positive = hydrates form) | K |
Method and standards
Towler–Mokhatab correlation.
Where it is used
- Flowline and pipeline flow assurance.
- Choke and letdown station design.
Common mistakes
- Applying it to gas without free water.
- Ignoring the Joule–Thomson cooling across chokes.
Assumptions and limits
- Sweet natural gas; Katz chart accuracy.
References
- Mokhatab
- Poe and Speight
- Handbook of Natural Gas Transmission and Processing (Gulf Professional Publishing, 2006)
- ch. 3
- eq. 3-53 (Towler and Mokhatab, 2005)
- Example 3-2
Questions and answers
Why do hydrates matter?
Ice-like solids of water and light gas form well above 0 °C at pipeline pressures and can block lines, valves and meters.
How accurate is the correlation?
It reproduces the Katz chart; in Mokhatab's Example 3-2 it gives 59.1 °F against 57.6 °F measured for a sour gas.
What do the defaults represent?
Mokhatab's Example 3-2: gravity 0.709 at 661.37 psia (59.1 °F), against a 40 °F line.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.