Worked example
Example: Hyperbolic b 0.5, 40 %/yr, 3 years. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Initial rate | 1,000.0 bbl/d |
| Initial decline rate (nominal) | 0.40000 1/a |
| Decline exponent (0 exponential, 1 harmonic) | 0.50000 - |
| Time | 3.0000 a |
Applying the formula below gives:
| Result | Value |
|---|---|
| Rate at time t | 390.62 bbl/d |
| Cumulative production to time t | 684,844 bbl |
| Effective annual decline in the first year | 30.556 % |
Open this example in the calculator and change any input.
Formula
\(q = \frac{q_i}{(1 + bD_it)^{1/b}}, \quad N_p = \frac{q_i^b}{(1 - b)D_i}\left(q_i^{1-b} - q^{1-b}\right)\)
\(q = q_ie^{-D_it},\ N_p = \frac{q_i - q}{D_i}\ (b = 0); \quad N_p = \frac{q_i}{D_i}\ln\frac{q_i}{q}\ (b = 1)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q_i\) | Initial rate | m³/s |
| \(D_i\) | Initial decline rate (nominal) | 1/s |
| \(b\) | Decline exponent (0 exponential, 1 harmonic) | - |
| \(t\) | Time | s |
| \(q(t)\) | Rate at time t | m³/s |
| \(N_p\) | Cumulative production to time t | m³ |
| \(D_e\) | Effective annual decline in the first year | - |
Method and standards
Arps' decline relations.
Where it is used
- Reserve and production forecasts.
- Economic limit and well life.
Common mistakes
- Mixing nominal and effective decline.
- Using b > 1 data from transient flow.
Assumptions and limits
- Boundary-dominated flow; constant operating conditions.
References
- Ahmed
- Reservoir Engineering Handbook
- 5th ed. (Gulf Professional Publishing, 2019)
- ch. 16 (Arps, 1945)
Questions and answers
Which b should I use?
0 (exponential) for conservative forecasts and strong pressure depletion; 0.3–0.6 for solution-gas drive; near 1 with good pressure support.
What is the difference between nominal and effective decline?
Nominal is the instantaneous rate; effective is the fall over a year: for exponential decline D_e = 1 − e^(−D_i).
What do the defaults represent?
1,000 bbl/d declining hyperbolically (b = 0.5) at 40 % per year nominal, after 3 years.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.