Worked example
Example: 35 °API, 375 scf/STB. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil gravity | 35.000 - |
| Solution gas-oil ratio | 375.00 scf/STB |
| Solution gas gravity (air = 1) | 0.75000 - |
| Oil formation volume factor | 1.2500 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oil specific gravity (60/60 °F) | 0.84985 |
| Stock-tank oil density | 849.01 kg/m³ |
| Oil density at reservoir conditions | 728.59 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\gamma_o = \frac{141.5}{\text{API} + 131.5}, \quad \rho_o = \frac{62.4\gamma_o + 0.0136R_s\gamma_g}{B_o}\ (\text{lb/ft}^3,\ R_s\ \text{scf/STB})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{API}\) | Oil gravity | - |
| \(R_s\) | Solution gas-oil ratio | m³/m³ |
| \(\gamma_g\) | Solution gas gravity (air = 1) | - |
| \(B_o\) | Oil formation volume factor | - |
| \(\gamma_o\) | Oil specific gravity (60/60 °F) | - |
| \(\rho_{st}\) | Stock-tank oil density | kg/m³ |
| \(\rho_o\) | Oil density at reservoir conditions | kg/m³ |
Method and standards
Mass balance of stock-tank oil and dissolved gas.
Where it is used
- Crude assays and tank gauging.
- PVT checks.
Common mistakes
- Confusing API with specific gravity.
- Using B_o at the wrong pressure.
Assumptions and limits
- Black-oil model.
References
- Ahmed
- Reservoir Engineering Handbook
- 5th ed. (Gulf Professional Publishing, 2019)
- ch. 2
- eqs. 2-67 and 2-92
Questions and answers
Why does API gravity rise as oil gets lighter?
API = 141.5/γ − 131.5 is an inverse scale; water is 10 °API.
Why is reservoir oil lighter than stock-tank oil?
Dissolved gas adds little mass but the oil swells by B_o.
What do the defaults represent?
A 35 °API crude with 375 scf/STB of 0.75-gravity gas and B_o = 1.25.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.