Worked example
Example: 100 MMSCFD in NPS 14 (24 mi) and NPS 12 (16 mi) loops. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Total flow (any basis) | 2,831,685 m³/d |
| Length of loop 1 | 38.624 km |
| Inside diameter of loop 1 | 342.90 mm |
| Length of loop 2 | 25.750 km |
| Inside diameter of loop 2 | 311.15 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow through loop 1 | 1,444,281 m³/d |
| Flow through loop 2 | 1,387,404 m³/d |
| Equivalent diameter over length L₁ | 448.87 mm |
Open this example in the calculator and change any input.
Formula
\(\frac{Q_1}{Q_2} = \left(\frac{L_2}{L_1}\right)^{0.5}\left(\frac{D_1}{D_2}\right)^{2.5}, \quad D_e = D_1\left(\frac{Q}{Q_1}\right)^{0.4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Total flow (any basis) | m³/s |
| \(L_1\) | Length of loop 1 | m |
| \(D_1\) | Inside diameter of loop 1 | m |
| \(L_2\) | Length of loop 2 | m |
| \(D_2\) | Inside diameter of loop 2 | m |
| \(Q_1\) | Flow through loop 1 | m³/s |
| \(Q_2\) | Flow through loop 2 | m³/s |
| \(D_e\) | Equivalent diameter over length L₁ | m |
Method and standards
Equal pressure drop in both loops.
Where it is used
- Debottlenecking with a loop.
- Twin lines between stations.
Common mistakes
- Mixing base and actual flows.
- Loops that do not share both ends.
Assumptions and limits
- Same F and temperature in both loops.
References
- Menon
- Gas Pipeline Hydraulics (CRC Press, 2005)
- ch. 3.7
- eqs. 3.10–3.17
Questions and answers
Why loop a pipeline?
A parallel loop over a bottleneck section lowers the pressure drop there, raising capacity without a new compressor.
Does the shorter loop carry more gas?
Yes, and the larger one too: flow goes as D^2.5/√L.
What do the defaults represent?
Menon's Example: 100 MMSCFD split between a 24-mile NPS 14 loop and a 16-mile NPS 12 loop (about 51 and 49 MMSCFD in his example, which uses slightly different bores).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.