Worked example
Example: Mokhatab Example 3-3, methanol. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hydrate formation temperature without inhibitor | 29.158 °C |
| Lowest line temperature | 9.4000 °C |
| Inhibitor | Methanol |
| Free water in the line | 100.00 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydrate depression needed | 19.758 K |
| Inhibitor in the water phase (Hammerschmidt) | 32.796 % |
| Inhibitor in the water phase (Nielsen–Bucklin) | 35.963 % |
| Inhibitor rate to the water phase (Hammerschmidt) | 48.801 kg/h |
Open this example in the calculator and change any input.
Formula
\(W = \frac{100\,M\Delta T}{K + M\Delta T}\ (\Delta T\ \text{in °F}), \quad \Delta T = -129.6\ln x_{H_2O}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_h\) | Hydrate formation temperature without inhibitor | K |
| \(T_l\) | Lowest line temperature | K |
| \(\text{inhibitor}\) | Inhibitor | - |
| \(\dot m_w\) | Free water in the line | kg/s |
| \(\Delta T\) | Hydrate depression needed | K |
| \(W\) | Inhibitor in the water phase (Hammerschmidt) | - |
| \(W_{NB}\) | Inhibitor in the water phase (Nielsen–Bucklin) | - |
| \(\dot m_i\) | Inhibitor rate to the water phase (Hammerschmidt) | kg/s |
Method and standards
Hammerschmidt (1934) and Nielsen–Bucklin (1983).
Where it is used
- Well and flowline start-up and shut-in.
- Continuous MEG injection design.
Common mistakes
- Forgetting losses to the gas phase.
- Using °C in the Hammerschmidt constant (it is for °F).
Assumptions and limits
- Water-phase concentration only.
References
- Mokhatab
- Poe and Speight
- Handbook of Natural Gas Transmission and Processing (Gulf Professional Publishing, 2006)
- ch. 3
- eqs. 3-54 and 3-55
- Table 3-6
- Example 3-3
Questions and answers
Methanol or glycol?
Methanol is cheap and works at low temperature but is lost to the gas; MEG is recovered and reused in continuous injection.
Why two results?
Hammerschmidt is reliable at moderate concentrations; Nielsen–Bucklin holds for higher methanol concentrations, up to about 50 %.
What do the defaults represent?
Mokhatab's Example 3-3: hydrate point 84.485 °F, line down to 48.92 °F, methanol (32.8 % by Hammerschmidt).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.