Worked example
Example: 3,000 to 2,500 psia after 10 Bcf. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Initial reservoir pressure | 3,000.0 psi |
| Z at initial pressure | 0.85000 - |
| Current reservoir pressure | 2,500.0 psi |
| Z at current pressure | 0.84000 - |
| Cumulative gas produced (standard) | 2.8317e+08 m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Initial p/z | 3,529.4 psi |
| Current p/z | 2,976.2 psi |
| Original gas in place (standard) | 1.8065e+09 m³ |
| Recovery to date | 15.675 % |
Open this example in the calculator and change any input.
Formula
\(\frac{p}{z} = \frac{p_i}{z_i}\left(1 - \frac{G_p}{G}\right) \;\Rightarrow\; G = G_p\frac{p_i/z_i}{p_i/z_i - p/z}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_i\) | Initial reservoir pressure | Pa |
| \(z_i\) | Z at initial pressure | - |
| \(p\) | Current reservoir pressure | Pa |
| \(z\) | Z at current pressure | - |
| \(G_p\) | Cumulative gas produced (standard) | m³ |
| \(p_i/z_i\) | Initial p/z | Pa |
| \(p/z\) | Current p/z | Pa |
| \(G\) | Original gas in place (standard) | m³ |
| \(G_p/G\) | Recovery to date | - |
Method and standards
Volumetric gas material balance.
Where it is used
- Reserves booking and depletion planning.
- Checking volumetric estimates.
Common mistakes
- Using surface pressures instead of reservoir pressures.
- Ignoring water drive.
Assumptions and limits
- Volumetric reservoir; no influx.
References
- Ahmed
- Reservoir Engineering Handbook
- 5th ed. (Gulf Professional Publishing, 2019)
- ch. 13 (gas reservoirs, volumetric material balance)
Questions and answers
Why plot p/z?
For a volumetric gas reservoir, p/z falls linearly with cumulative production, so two or more points fix the gas in place.
What if the points curve upward?
Water influx or a connected aquifer is supporting pressure; a simple p/z line then overstates the gas in place.
What do the defaults represent?
A reservoir that fell from 3,000 to 2,500 psia after producing 10 Bcf.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.