FireCADCalc

Solution Gas-Oil Ratio: Standing, Glasø, Marhoun, Petrosky–Farshad

Gas solubility in crude oil at a pressure and temperature by four black-oil correlations, from oil API gravity and gas gravity, for comparison.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 35 API crude at 200 F and 2500 psia

Accepted: 14.504 to 14,504 psi
Accepted: 44.33 to 350.33 °F
Accepted: 10 to 60
Accepted: 0.55 to 1.5

Results

Valid at or below the bubble point; above it R_s stays at its bubble-point value. The comparison on six crudes: Standing 10 %, Glasø 5.8 %, Marhoun 12.4 %, Petrosky–Farshad 7.8 % average error. Vasquez–Beggs is on its own page.

Standing623.77scf/STB
Glasø537.66scf/STB
Marhoun568.39scf/STB
Petrosky–Farshad534.37scf/STB
Stock-tank oil specific gravity0.84985

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 35 API crude at 200 F and 2500 psia. The inputs, in the units selected above:

InputValue
Pressure (at or below the bubble point)2,515.0 psi
Temperature200.00 °F
Oil gravity35.000 -
Gas gravity (air = 1)0.80000 -

Applying the formula below gives:

ResultValue
Standing623.77 scf/STB
Glasø537.66 scf/STB
Marhoun568.39 scf/STB
Petrosky–Farshad534.37 scf/STB
Stock-tank oil specific gravity0.84985

Open this example in the calculator and change any input.

Formula

\(R_s = \gamma_g\left[\left(\frac{p}{18.2} + 1.4\right)10^{0.0125API - 0.00091T}\right]^{1.2048}, \quad R_s = \gamma_g\left[\frac{API^{0.989}}{T^{0.172}}p_b^*\right]^{1.2255}, \quad R_s = \left[\left(\frac{p}{112.727} + 12.34\right)\gamma_g^{0.8439}10^x\right]^{1.73184}\)

Variables

Symbol Meaning SI unit
\(p\) Pressure (at or below the bubble point) Pa
\(T\) Temperature K
\(API\) Oil gravity -
\(\gamma_g\) Gas gravity (air = 1) -
\(R_{s,Standing}\) Standing m³/m³
\(R_{s,Glaso}\) Glasø m³/m³
\(R_{s,Marhoun}\) Marhoun m³/m³
\(R_{s,PF}\) Petrosky–Farshad m³/m³
\(\gamma_o\) Stock-tank oil specific gravity -

Method and standards

Black-oil gas solubility correlations (psia, °F, °R).

Where it is used

  • PVT estimates without a lab report.
  • Checking lab data for consistency.

Common mistakes

  • Using it above the bubble point.
  • Using separator gas gravity in Standing's form.

Assumptions and limits

  • Black oils; hydrocarbon gas.

Questions and answers

Why do the correlations disagree?

Each was fitted to crudes from one region: Standing to California, Glasø to the North Sea, Marhoun to the Middle East, Petrosky–Farshad to the Gulf of Mexico. Use the one closest to your crude.

Which gas gravity?

The total surface gas gravity; Vasquez–Beggs uses a separator-corrected gravity instead.

What do the defaults represent?

An illustrative case: 35 API crude at 200 F and 2500 psia. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 2, eqs. 2-70 to 2-75 and Examples 2-18 to 2-22

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.