Worked example
Example: 35 API crude at 200 F and 2500 psia. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure (at or below the bubble point) | 2,515.0 psi |
| Temperature | 200.00 °F |
| Oil gravity | 35.000 - |
| Gas gravity (air = 1) | 0.80000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Standing | 623.77 scf/STB |
| Glasø | 537.66 scf/STB |
| Marhoun | 568.39 scf/STB |
| Petrosky–Farshad | 534.37 scf/STB |
| Stock-tank oil specific gravity | 0.84985 |
Open this example in the calculator and change any input.
Formula
\(R_s = \gamma_g\left[\left(\frac{p}{18.2} + 1.4\right)10^{0.0125API - 0.00091T}\right]^{1.2048}, \quad R_s = \gamma_g\left[\frac{API^{0.989}}{T^{0.172}}p_b^*\right]^{1.2255}, \quad R_s = \left[\left(\frac{p}{112.727} + 12.34\right)\gamma_g^{0.8439}10^x\right]^{1.73184}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Pressure (at or below the bubble point) | Pa |
| \(T\) | Temperature | K |
| \(API\) | Oil gravity | - |
| \(\gamma_g\) | Gas gravity (air = 1) | - |
| \(R_{s,Standing}\) | Standing | m³/m³ |
| \(R_{s,Glaso}\) | Glasø | m³/m³ |
| \(R_{s,Marhoun}\) | Marhoun | m³/m³ |
| \(R_{s,PF}\) | Petrosky–Farshad | m³/m³ |
| \(\gamma_o\) | Stock-tank oil specific gravity | - |
Method and standards
Black-oil gas solubility correlations (psia, °F, °R).
Where it is used
- PVT estimates without a lab report.
- Checking lab data for consistency.
Common mistakes
- Using it above the bubble point.
- Using separator gas gravity in Standing's form.
Assumptions and limits
- Black oils; hydrocarbon gas.
Questions and answers
Why do the correlations disagree?
Each was fitted to crudes from one region: Standing to California, Glasø to the North Sea, Marhoun to the Middle East, Petrosky–Farshad to the Gulf of Mexico. Use the one closest to your crude.
Which gas gravity?
The total surface gas gravity; Vasquez–Beggs uses a separator-corrected gravity instead.
What do the defaults represent?
An illustrative case: 35 API crude at 200 F and 2500 psia. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 2, eqs. 2-70 to 2-75 and Examples 2-18 to 2-22