Worked example
Example: Condensate at 300 psia wellhead, 2 3/8 in tubing. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flowing pressure at the point checked (absolute) | 300.00 psi |
| Temperature at that point | 80.330 °F |
| Tubing inside diameter | 1.9950 in |
| Liquid density (water about 67, condensate about 45 lb/ft³) | 45.000 lb/ft³ |
| Gas-liquid surface tension | 20.000 mN/m |
| Gas gravity (air = 1) | 0.70000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas compressibility factor (Hall–Yarborough) | 0.94068 |
| Gas density | 1.1156 lb/ft³ |
| Critical (terminal) velocity with Turner's 20 % margin | 9.8529 ft/s |
| Minimum gas rate to unload liquids | 387.61 Mscf/d |
Open this example in the calculator and change any input.
Formula
\(v_t = 1.912\frac{[\sigma(\rho_L - \rho_g)]^{1/4}}{\rho_g^{1/2}}\ (\text{ft/s}), \quad Q_{min} = \frac{128\,r^2p\,[\sigma(\rho_L - \rho_g)]^{1/4}}{TZ\sqrt{\rho_g}}\ (\text{Mscf/d; in, psia, °R, dyn/cm, lb/ft}^3)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Flowing pressure at the point checked (absolute) | Pa |
| \(T\) | Temperature at that point | K |
| \(d\) | Tubing inside diameter | m |
| \(\rho_L\) | Liquid density (water about 67, condensate about 45 lb/ft³) | kg/m³ |
| \(\sigma\) | Gas-liquid surface tension | N/m |
| \(\gamma_g\) | Gas gravity (air = 1) | - |
| \(Z\) | Gas compressibility factor (Hall–Yarborough) | - |
| \(\rho_g\) | Gas density | kg/m³ |
| \(v_t\) | Critical (terminal) velocity with Turner's 20 % margin | m/s |
| \(Q_{min}\) | Minimum gas rate to unload liquids | Nm³/s |
Method and standards
Turner droplet model with 20 % margin.
Where it is used
- Velocity string and tubing design.
- Deciding when to install artificial lift on gas wells.
Common mistakes
- Using the bottom-hole value only.
- Using the casing instead of the tubing diameter.
Assumptions and limits
- Droplet model; mist flow.
Questions and answers
Why is water harder to lift than condensate?
It is denser and has a higher surface tension, so its largest stable droplets are bigger and need a faster gas stream.
Where should I check?
Usually at the wellhead (lowest pressure, highest velocity is not guaranteed); Turner's original work found the wellhead governs in most wells.
What do the defaults represent?
An illustrative case: Condensate at 300 psia wellhead, 2 3/8 in tubing. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 8, eq. 8-61 and Example 8-10 (Turner, Hubbard and Dukler, 1969), Hall and Yarborough (1973) Z-factor equation (engine)