FireCADCalc

Undersaturated Oil Compressibility and Bo Above the Bubble Point

Isothermal compressibility of oil above the bubble point and the shrinking oil formation volume factor by Vasquez–Beggs and Petrosky–Farshad.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Heavy oil 25 API, 6000 psia

Accepted: 14.504 to 21,756 psi
Accepted: 14.504 to 14,504 psi
Accepted: 1 to 4
Accepted: 5.6146 to 5,614.6 scf/STB
Accepted: 0.55 to 1.5
Accepted: 10 to 60
Accepted: 44.33 to 350.33 °F
Accepted: 14.504 to 1,450.4 psi
Accepted: -9.67 to 260.33 °F

Results

B_o above the bubble point integrates c_o from p_b: oil is compressed and B_o falls slowly with pressure. The comparison: Vasquez–Beggs 6.2 %, Petrosky–Farshad 4.1 % average error on c_o.

Oil compressibility (Vasquez–Beggs)4.1654e-061/psi
Oil compressibility (Petrosky–Farshad)4.8067e-061/psi
B_o at the pressure (Vasquez–Beggs)1.1911
B_o at the pressure (Petrosky–Farshad)1.1908
Gas gravity at 100 psig separator0.75000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Heavy oil 25 API, 6000 psia. The inputs, in the units selected above:

InputValue
Pressure (above the bubble point)6,000.0 psi
Bubble-point pressure3,200.0 psi
Oil formation volume factor at the bubble point1.2100 -
Solution GOR at the bubble point350.00 scf/STB
Gas gravity (air = 1)0.75000 -
Oil gravity25.000 -
Temperature160.00 °F
Separator pressure (for Vasquez–Beggs)114.70 psi
Separator temperature80.000 °F

Applying the formula below gives:

ResultValue
Oil compressibility (Vasquez–Beggs)4.1654e-06 1/psi
Oil compressibility (Petrosky–Farshad)4.8067e-06 1/psi
B_o at the pressure (Vasquez–Beggs)1.1911
B_o at the pressure (Petrosky–Farshad)1.1908
Gas gravity at 100 psig separator0.75000

Open this example in the calculator and change any input.

Formula

\(c_o = \frac{-1433 + 5R_{sb} + 17.2T - 1180\gamma_{gs} + 12.61API}{10^5p}, \quad B_o = B_{ob}\exp\left[-A\ln\frac{p}{p_b}\right], \quad B_o = B_{ob}\exp\left[A_{PF}\left(p_b^{0.4094} - p^{0.4094}\right)\right]\)

Variables

Symbol Meaning SI unit
\(p\) Pressure (above the bubble point) Pa
\(p_b\) Bubble-point pressure Pa
\(B_{ob}\) Oil formation volume factor at the bubble point -
\(R_{sb}\) Solution GOR at the bubble point m³/m³
\(\gamma_g\) Gas gravity (air = 1) -
\(API\) Oil gravity -
\(T\) Temperature K
\(p_{sep}\) Separator pressure (for Vasquez–Beggs) Pa
\(T_{sep}\) Separator temperature K
\(c_{o,VB}\) Oil compressibility (Vasquez–Beggs) 1/Pa
\(c_{o,PF}\) Oil compressibility (Petrosky–Farshad) 1/Pa
\(B_{o,VB}\) B_o at the pressure (Vasquez–Beggs) -
\(B_{o,PF}\) B_o at the pressure (Petrosky–Farshad) -
\(\gamma_{gs}\) Gas gravity at 100 psig separator -

Method and standards

Vasquez–Beggs and Petrosky–Farshad (psia, °F).

Where it is used

  • Well test total compressibility.
  • Undersaturated reservoir material balance.

Common mistakes

  • Using it below the bubble point.
  • Using gauge pressures.

Assumptions and limits

  • Undersaturated black oil.

Questions and answers

Where is c_o used?

In total compressibility for well tests and transient flow, and in the material balance of undersaturated reservoirs.

Why does B_o fall above the bubble point?

No more gas can dissolve, so raising the pressure only compresses the oil.

What do the defaults represent?

An illustrative case: Heavy oil 25 API, 6000 psia. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 2, eqs. 2-97 to 2-110 and Examples 2-31 and 2-33

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.