Worked example
Example: Heavy oil 25 API, 6000 psia. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure (above the bubble point) | 6,000.0 psi |
| Bubble-point pressure | 3,200.0 psi |
| Oil formation volume factor at the bubble point | 1.2100 - |
| Solution GOR at the bubble point | 350.00 scf/STB |
| Gas gravity (air = 1) | 0.75000 - |
| Oil gravity | 25.000 - |
| Temperature | 160.00 °F |
| Separator pressure (for Vasquez–Beggs) | 114.70 psi |
| Separator temperature | 80.000 °F |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oil compressibility (Vasquez–Beggs) | 4.1654e-06 1/psi |
| Oil compressibility (Petrosky–Farshad) | 4.8067e-06 1/psi |
| B_o at the pressure (Vasquez–Beggs) | 1.1911 |
| B_o at the pressure (Petrosky–Farshad) | 1.1908 |
| Gas gravity at 100 psig separator | 0.75000 |
Open this example in the calculator and change any input.
Formula
\(c_o = \frac{-1433 + 5R_{sb} + 17.2T - 1180\gamma_{gs} + 12.61API}{10^5p}, \quad B_o = B_{ob}\exp\left[-A\ln\frac{p}{p_b}\right], \quad B_o = B_{ob}\exp\left[A_{PF}\left(p_b^{0.4094} - p^{0.4094}\right)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Pressure (above the bubble point) | Pa |
| \(p_b\) | Bubble-point pressure | Pa |
| \(B_{ob}\) | Oil formation volume factor at the bubble point | - |
| \(R_{sb}\) | Solution GOR at the bubble point | m³/m³ |
| \(\gamma_g\) | Gas gravity (air = 1) | - |
| \(API\) | Oil gravity | - |
| \(T\) | Temperature | K |
| \(p_{sep}\) | Separator pressure (for Vasquez–Beggs) | Pa |
| \(T_{sep}\) | Separator temperature | K |
| \(c_{o,VB}\) | Oil compressibility (Vasquez–Beggs) | 1/Pa |
| \(c_{o,PF}\) | Oil compressibility (Petrosky–Farshad) | 1/Pa |
| \(B_{o,VB}\) | B_o at the pressure (Vasquez–Beggs) | - |
| \(B_{o,PF}\) | B_o at the pressure (Petrosky–Farshad) | - |
| \(\gamma_{gs}\) | Gas gravity at 100 psig separator | - |
Method and standards
Vasquez–Beggs and Petrosky–Farshad (psia, °F).
Where it is used
- Well test total compressibility.
- Undersaturated reservoir material balance.
Common mistakes
- Using it below the bubble point.
- Using gauge pressures.
Assumptions and limits
- Undersaturated black oil.
Questions and answers
Where is c_o used?
In total compressibility for well tests and transient flow, and in the material balance of undersaturated reservoirs.
Why does B_o fall above the bubble point?
No more gas can dissolve, so raising the pressure only compresses the oil.
What do the defaults represent?
An illustrative case: Heavy oil 25 API, 6000 psia. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 2, eqs. 2-97 to 2-110 and Examples 2-31 and 2-33