FireCADCalc

Sour Gas Z-Factor: Wichert–Aziz and Carr–Kobayashi–Burrows

Pseudo-critical properties of a sour natural gas corrected for CO₂, H₂S and N₂ by Wichert–Aziz and Carr–Kobayashi–Burrows, with Z and gas density.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Acid gas 20 % CO2, 2 % H2S, 3 % N2 at 2000 psiaSour condensate, 4 % CO2, 15 % H2S at 5000 psia

Accepted: 0.55 to 1.8
Accepted: 0 to 80 %
Accepted: 0 to 80 %
Accepted: 0 to 50 %
Accepted: 14.504 to 14,504 psi
Accepted: 8.33 to 440.33 °F

Results

Wichert–Aziz needs only CO₂ and H₂S and is the usual choice; Carr–Kobayashi–Burrows also corrects for nitrogen and needs no composition beyond the three mole fractions. Z is solved by Hall–Yarborough with the corrected properties.

Pseudo-critical temperature, uncorrected-23.699°F
Pseudo-critical pressure, uncorrected646.87psi
Wichert–Aziz adjustment24.303°F
Corrected T_pc (Wichert–Aziz)-48.002°F
Corrected p_pc (Wichert–Aziz)606.50psi
Z factor (Wichert–Aziz, Hall–Yarborough)1.0332
Gas density (Wichert–Aziz)17.481lb/ft³
Corrected T_pc (Carr–Kobayashi–Burrows)-9.8988°F
Corrected p_pc (Carr–Kobayashi–Burrows)752.77psi
Z factor (Carr–Kobayashi–Burrows, Hall–Yarborough)0.91792
Gas density (Carr–Kobayashi–Burrows)19.677lb/ft³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Acid gas 20 % CO2, 2 % H2S, 3 % N2 at 2000 psia. The inputs, in the units selected above:

InputValue
Gas gravity (air = 1)0.85000 -
CO₂ mole fraction20.000 %
H₂S mole fraction2.0000 %
N₂ mole fraction3.0000 %
Gas type (for Standing's pseudo-critical properties)Natural gas
Pressure (absolute)2,000.0 psi
Temperature200.00 °F

Applying the formula below gives:

ResultValue
Pseudo-critical temperature, uncorrected-24.451 °F
Pseudo-critical pressure, uncorrected662.66 psi
Wichert–Aziz adjustment22.194 °F
Corrected T_pc (Wichert–Aziz)-46.646 °F
Corrected p_pc (Wichert–Aziz)628.24 psi
Z factor (Wichert–Aziz, Hall–Yarborough)0.82136
Gas density (Wichert–Aziz)8.4669 lb/ft³
Corrected T_pc (Carr–Kobayashi–Burrows)-45.351 °F
Corrected p_pc (Carr–Kobayashi–Burrows)757.56 psi
Z factor (Carr–Kobayashi–Burrows, Hall–Yarborough)0.83168
Gas density (Carr–Kobayashi–Burrows)8.3618 lb/ft³

Open this example in the calculator and change any input.

Formula

\(\varepsilon = 120(A^{0.9} - A^{1.6}) + 15(B^{0.5} - B^4), \quad T'_{pc} = T_{pc} - \varepsilon, \quad p'_{pc} = \frac{p_{pc}T'_{pc}}{T_{pc} + B(1 - B)\varepsilon}, \quad A = y_{H_2S} + y_{CO_2},\ B = y_{H_2S}\)

Variables

Symbol Meaning SI unit
\(\gamma_g\) Gas gravity (air = 1) -
\(y_{CO_2}\) CO₂ mole fraction -
\(y_{H_2S}\) H₂S mole fraction -
\(y_{N_2}\) N₂ mole fraction -
\(\text{type}\) Gas type (for Standing's pseudo-critical properties) -
\(p\) Pressure (absolute) Pa
\(T\) Temperature K
\(T_{pc}\) Pseudo-critical temperature, uncorrected K
\(p_{pc}\) Pseudo-critical pressure, uncorrected Pa
\(\varepsilon\) Wichert–Aziz adjustment K
\(T'_{pc}\) Corrected T_pc (Wichert–Aziz) K
\(p'_{pc}\) Corrected p_pc (Wichert–Aziz) Pa
\(Z_{WA}\) Z factor (Wichert–Aziz, Hall–Yarborough) -
\(\rho_{WA}\) Gas density (Wichert–Aziz) kg/m³
\(T'_{pc,CKB}\) Corrected T_pc (Carr–Kobayashi–Burrows) K
\(p'_{pc,CKB}\) Corrected p_pc (Carr–Kobayashi–Burrows) Pa
\(Z_{CKB}\) Z factor (Carr–Kobayashi–Burrows, Hall–Yarborough) -
\(\rho_{CKB}\) Gas density (Carr–Kobayashi–Burrows) kg/m³

Method and standards

Wichert–Aziz and Carr–Kobayashi–Burrows corrections (°R, psia).

Where it is used

  • Sour gas reserves and pipeline calculations.
  • Amine unit and compressor design.

Common mistakes

  • Correcting twice (composition already in Kay's rule).
  • Using mole percent instead of fraction.

Assumptions and limits

  • Hall–Yarborough range 1.05 ≤ T_pr ≤ 3.

Questions and answers

Why do CO₂ and H₂S need a correction?

They are polar and their molecules interact differently from hydrocarbons, so a sour gas is less compressible than Kay's or Standing's pseudo-critical properties predict.

Which method should I use?

Wichert–Aziz is the most widely used and works to about 80 % acid gas; use Carr–Kobayashi–Burrows when only the three non-hydrocarbon fractions are known and nitrogen is significant.

What do the defaults represent?

An illustrative case: Acid gas 20 % CO2, 2 % H2S, 3 % N2 at 2000 psia. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 2, eqs. 2-22 to 2-26 and Examples 2-8 and 2-9, Hall and Yarborough (1973) Z-factor equation (engine)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.