Worked example
Example: Illustrative associated gas. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Propane | 4.0000 % |
| Isobutane | 0.80000 % |
| n-Butane | 1.2000 % |
| Isopentane | 0.40000 % |
| n-Pentane | 0.40000 % |
| Hexanes plus (as n-hexane) | 0.50000 % |
| Gas flow | 180,000 Nm³/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| C₃+ liquid content (US gal/Mscf) | 2.2340 |
| C₄+ liquid content (US gal/Mscf) | 1.1343 |
| Potential C₃+ liquid | 56.817 m³/h |
Open this example in the calculator and change any input.
Formula
\(GPM_i = \frac{1000y_i}{379.49}\left(\frac{\text{gal}}{\text{lbmol}}\right)_i, \quad GPM = \sum_iGPM_i\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_{C_3}\) | Propane | - |
| \(y_{iC_4}\) | Isobutane | - |
| \(y_{nC_4}\) | n-Butane | - |
| \(y_{iC_5}\) | Isopentane | - |
| \(y_{nC_5}\) | n-Pentane | - |
| \(y_{C_6+}\) | Hexanes plus (as n-hexane) | - |
| \(Q\) | Gas flow | Nm³/s |
| \(GPM_{C_3+}\) | C₃+ liquid content (US gal/Mscf) | - |
| \(GPM_{C_4+}\) | C₄+ liquid content (US gal/Mscf) | - |
| \(\dot V_L\) | Potential C₃+ liquid | m³/s |
Method and standards
Gas liquids content.
Where it is used
- Gas plant feasibility and NGL recovery.
- Valuing rich associated gas.
Common mistakes
- Mixing mole and volume percent.
- Assuming full recovery of every component.
Assumptions and limits
- Ideal gas at 60 °F, 14.696 psia; hexanes plus treated as n-hexane.
References
- GPM from composition with liquid molar volumes
Questions and answers
What does GPM mean?
US gallons of liquid product recoverable per thousand standard cubic feet of gas, if every molecule of that component were recovered.
Which gases are 'rich'?
Gases above about 3–4 GPM of C₂+ or C₃+; lean pipeline gas is often below 1.
What do the defaults represent?
An illustrative associated gas with 4 % propane, 2 % butanes, 0.8 % pentanes and 0.5 % hexanes plus.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
GPSA Engineering Data Book, 12th ed. (Gas Processors Suppliers Association, 2004)