FireCADCalc

Natural Gas Water Content (Bukacek Correlation)

Saturated water content of sweet natural gas at a pressure and temperature by the Bukacek correlation, in lb/MMscf and mg/Sm³, with the water to remove to a target.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative 70 bar(a), 30 CLow pressure 10 bar(a), 40 CCold 100 bar(a), 10 C

Accepted: 1 to 200 bar
Accepted: -10 to 100 °C
Accepted: 36 to 3,600,000 Nm³/h
Accepted: 0.5 to 200

Results

Bukacek: W = 47,484·p_v/P + B, log₁₀B = −3,083.87/(459.6 + T) + 6.69449 (W in lb/MMscf, P and p_v in psia, T in °F); 1 lb/MMscf ≈ 16.02 mg/Sm³. Good within a few percent for sweet, lean gas; acid gases and heavy hydrocarbons change it. Pipeline specifications are often 4–7 lb/MMscf. Gas flow is entered at normal conditions and converted to scf at 60 °F.

Saturated water content (lb/MMscf)10.227
Saturated water content per standard m³ (15 °C)163.82mg/m³
Water to remove18.976kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 70 bar(a), 30 C. The inputs, in the units selected above:

InputValue
Gas pressure (absolute)70.000 bar
Gas temperature30.000 °C
Gas flow (standard)360,000 Nm³/h
Target water content (lb/MMscf)7.0000 -

Applying the formula below gives:

ResultValue
Saturated water content (lb/MMscf)39.828
Saturated water content per standard m³ (15 °C)637.99 mg/m³
Water to remove200.09 kg/h

Open this example in the calculator and change any input.

Formula

\(W = 47484\frac{p_v}{P} + B, \quad \log_{10}B = \frac{-3083.87}{459.6 + T_F} + 6.69449\)

Variables

Symbol Meaning SI unit
\(P\) Gas pressure (absolute) Pa
\(T\) Gas temperature K
\(Q\) Gas flow (standard) Nm³/s
\(W_t\) Target water content (lb/MMscf) -
\(W\) Saturated water content (lb/MMscf) -
\(W_{SI}\) Saturated water content per standard m³ (15 °C) kg/m³
\(\dot m_w\) Water to remove kg/s

Method and standards

Water content.

Where it is used

  • Gas dehydration unit sizing.
  • Hydrate and corrosion risk checks.

Common mistakes

  • Using gauge pressure.
  • Applying it to sour gas without correction.

Assumptions and limits

  • Sweet lean gas in equilibrium with liquid water.

References

  • Bukacek water content correlation

Questions and answers

Why does water content fall with pressure?

Water vapour pressure is fixed by temperature; at higher total pressure it is a smaller fraction of the gas.

Is Bukacek valid for sour gas?

Not well: H₂S and CO₂ hold more water; use corrections or an equation of state.

What do the defaults represent?

An illustrative 360,000 Nm³/h of gas at 70 bar(a) and 30 °C, dried to 7 lb/MMscf.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bukacek, Equilibrium moisture content of natural gases, IGT Research Bulletin 8 (1955), GPSA Engineering Data Book, 12th ed. (Gas Processors Suppliers Association, 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.