Gas Pipeline Compressor Station Spacing

Spacing between compressor stations and the number needed on a gas pipeline from maximum pressure, compression ratio and delivery pressure (general flow equation).

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas system

Inputs

Examples: 15 Mm3/day, 590 mm, 400 kmShort line, one stationMany stations

Results

Flat route, one transmission factor and temperature; stations are spaced so each discharges at P_d and the next receives at P_d/r. Refine locations with the elevation profile and fuel use.

Station suction pressure5,384.6kPa
Spacing between stations138.65km
Longest last section that still delivers at P_del228.71km
Compressor stations needed (including the first)1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15 Mm3/day, 590 mm, 400 km. The inputs, in the units selected above:

InputValue
Gas flow at base conditions1.5000e+07 m³/d
Pipe inside diameter590.00 mm
Total pipeline length400.00 km
Transmission factor20.000 -
Gas gravity (air = 1)0.60000 -
Average gas temperature20.000 °C
Compressibility factor0.88000 -
Station discharge pressure (absolute, at most the MAOP)8,400.0 kPa
Compression ratio1.4000 -
Delivery pressure required (absolute)4,000.0 kPa
Base temperature15.000 °C
Base pressure101.33 kPa

Applying the formula below gives:

ResultValue
Station suction pressure6,000.0 kPa
Spacing between stations75.801 km
Longest last section that still delivers at P_del119.67 km
Compressor stations needed (including the first)5.0000

Open this example in the calculator and change any input.

Formula

\(K = GT_fZ\left(\frac{Q_b}{5.747\times10^{-4}F\frac{T_b}{P_b}D^{2.5}}\right)^2, \quad L_s = \frac{P_d^2 - (P_d/r)^2}{K}, \quad L_{last} = \frac{P_d^2 - P_{del}^2}{K}\)

Variables

Symbol Meaning SI unit
\(Q_b\) Gas flow at base conditions m³/s
\(D\) Pipe inside diameter m
\(L_t\) Total pipeline length m
\(F\) Transmission factor -
\(G\) Gas gravity (air = 1) -
\(T_f\) Average gas temperature K
\(Z\) Compressibility factor -
\(P_d\) Station discharge pressure (absolute, at most the MAOP) Pa
\(r\) Compression ratio -
\(P_{del}\) Delivery pressure required (absolute) Pa
\(T_b\) Base temperature K
\(P_b\) Base pressure Pa
\(P_s\) Station suction pressure Pa
\(L_s\) Spacing between stations m
\(L_{last}\) Longest last section that still delivers at P_del m
\(n\) Compressor stations needed (including the first) -

Method and standards

General flow equation solved for length between pressure limits (Menon's SI form).

Where it is used

  • Early route studies for gas transmission.
  • Checking whether a mid-line booster is needed.

Common mistakes

  • Using gauge pressures.
  • Ignoring elevation on hilly routes.

Assumptions and limits

  • Flat route; constant F, Z and T.

References

  • Menon
  • Gas Pipeline Hydraulics (CRC Press, 2005)
  • ch. 4.1 (compressor station locations) with the general flow equation 2.6

Questions and answers

Why not one large compressor?

Pipe strength caps the discharge pressure (MAOP), so a long line needs pressure restored at intervals.

What compression ratio is usual?

About 1.2–1.5 for transmission stations, a compromise between station count and power.

What do the defaults represent?

15 million m³/day through a 590 mm bore, 400 km, discharging at 8.4 MPa with a ratio of 1.4 and delivering at 4 MPa.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.