Worked example
Example: 15 Mm3/day, 590 mm, 400 km. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow at base conditions | 1.5000e+07 m³/d |
| Pipe inside diameter | 590.00 mm |
| Total pipeline length | 400.00 km |
| Transmission factor | 20.000 - |
| Gas gravity (air = 1) | 0.60000 - |
| Average gas temperature | 20.000 °C |
| Compressibility factor | 0.88000 - |
| Station discharge pressure (absolute, at most the MAOP) | 8,400.0 kPa |
| Compression ratio | 1.4000 - |
| Delivery pressure required (absolute) | 4,000.0 kPa |
| Base temperature | 15.000 °C |
| Base pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Station suction pressure | 6,000.0 kPa |
| Spacing between stations | 75.801 km |
| Longest last section that still delivers at P_del | 119.67 km |
| Compressor stations needed (including the first) | 5.0000 |
Open this example in the calculator and change any input.
Formula
\(K = GT_fZ\left(\frac{Q_b}{5.747\times10^{-4}F\frac{T_b}{P_b}D^{2.5}}\right)^2, \quad L_s = \frac{P_d^2 - (P_d/r)^2}{K}, \quad L_{last} = \frac{P_d^2 - P_{del}^2}{K}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_b\) | Gas flow at base conditions | m³/s |
| \(D\) | Pipe inside diameter | m |
| \(L_t\) | Total pipeline length | m |
| \(F\) | Transmission factor | - |
| \(G\) | Gas gravity (air = 1) | - |
| \(T_f\) | Average gas temperature | K |
| \(Z\) | Compressibility factor | - |
| \(P_d\) | Station discharge pressure (absolute, at most the MAOP) | Pa |
| \(r\) | Compression ratio | - |
| \(P_{del}\) | Delivery pressure required (absolute) | Pa |
| \(T_b\) | Base temperature | K |
| \(P_b\) | Base pressure | Pa |
| \(P_s\) | Station suction pressure | Pa |
| \(L_s\) | Spacing between stations | m |
| \(L_{last}\) | Longest last section that still delivers at P_del | m |
| \(n\) | Compressor stations needed (including the first) | - |
Method and standards
General flow equation solved for length between pressure limits (Menon's SI form).
Where it is used
- Early route studies for gas transmission.
- Checking whether a mid-line booster is needed.
Common mistakes
- Using gauge pressures.
- Ignoring elevation on hilly routes.
Assumptions and limits
- Flat route; constant F, Z and T.
References
- Menon
- Gas Pipeline Hydraulics (CRC Press, 2005)
- ch. 4.1 (compressor station locations) with the general flow equation 2.6
Questions and answers
Why not one large compressor?
Pipe strength caps the discharge pressure (MAOP), so a long line needs pressure restored at intervals.
What compression ratio is usual?
About 1.2–1.5 for transmission stations, a compromise between station count and power.
What do the defaults represent?
15 million m³/day through a 590 mm bore, 400 km, discharging at 8.4 MPa with a ratio of 1.4 and delivering at 4 MPa.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.