Worked example
Example: 35 API crude, 650 scf/STB at 200 F. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solution gas-oil ratio at the bubble point | 650.00 scf/STB |
| Gas gravity (air = 1) | 0.80000 - |
| Oil gravity | 35.000 - |
| Reservoir temperature | 200.00 °F |
| Separator pressure (for Vasquez–Beggs) | 114.70 psi |
| Separator temperature | 70.000 °F |
Applying the formula below gives:
| Result | Value |
|---|---|
| Standing | 2,603.1 psi |
| Vasquez–Beggs | 2,889.4 psi |
| Glasø | 2,943.0 psi |
| Marhoun | 2,768.3 psi |
| Petrosky–Farshad | 2,982.8 psi |
| Gas gravity corrected to 100 psig separator | 0.80000 |
Open this example in the calculator and change any input.
Formula
\(p_b = 18.2\left[\left(\frac{R_s}{\gamma_g}\right)^{0.83}10^a - 1.4\right], \quad \log p_b = 1.7669 + 1.7447\log p_b^* - 0.30218(\log p_b^*)^2, \quad p_b = aR_s^b\gamma_g^c\gamma_o^dT^e\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(R_s\) | Solution gas-oil ratio at the bubble point | m³/m³ |
| \(\gamma_g\) | Gas gravity (air = 1) | - |
| \(API\) | Oil gravity | - |
| \(T\) | Reservoir temperature | K |
| \(p_{sep}\) | Separator pressure (for Vasquez–Beggs) | Pa |
| \(T_{sep}\) | Separator temperature | K |
| \(p_{b,Standing}\) | Standing | Pa |
| \(p_{b,VB}\) | Vasquez–Beggs | Pa |
| \(p_{b,Glaso}\) | Glasø | Pa |
| \(p_{b,Marhoun}\) | Marhoun | Pa |
| \(p_{b,PF}\) | Petrosky–Farshad | Pa |
| \(\gamma_{gs}\) | Gas gravity corrected to 100 psig separator | - |
Method and standards
Black-oil bubble-point correlations (psia, °F, °R).
Where it is used
- Reservoir fluid screening.
- Choosing between single-phase and two-phase inflow models.
Common mistakes
- Using gauge pressure.
- Mixing separator and total gas gravities.
Assumptions and limits
- Black oils; no significant non-hydrocarbons.
Questions and answers
Why does the bubble point matter?
Above it the reservoir produces single-phase oil; below it free gas forms, the gas-oil ratio climbs and the inflow follows Vogel instead of a straight line.
Which separator conditions should I enter?
The first-stage separator pressure and temperature; they correct the gas gravity to a 100 psig basis for Vasquez–Beggs only.
What do the defaults represent?
An illustrative case: 35 API crude, 650 scf/STB at 200 F. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 2, eqs. 2-76 to 2-82 and Examples 2-24 to 2-29