Worked example
Example: 50 MMscfd, 2 % acid gas, 20 % MEA at 0.33. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow to the contactor | 50.000 MMscfd |
| Acid gas (H₂S + CO₂) in the inlet gas | 2.0000 % |
| Amine | MEA (monoethanolamine) |
| Amine strength in the solution | 20.000 % |
| Solution density at 60 °F | 8.4100 lb/US gal |
| Acid gas loading (mol acid gas per mol amine) | 0.33000 - |
| Excess circulation margin | 10.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Solution circulation (no margin) | 201.39 US gal/min |
| Design circulation with margin | 221.53 US gal/min |
| Acid gas removed | 49.804 kmol/h |
| Molar mass of the amine | 61.084 kg/kmol |
| Amine circulated (100 % basis) | 9,218.8 kg/h |
Open this example in the calculator and change any input.
Formula
\(Q = \frac{\dot n_{AG}M/AG}{WF\,\rho}, \quad \dot n_{AG} = \frac{Q_G\,MF}{V_m}; \quad \text{field form } Q[\text{gpm}] = \frac{k\,Q_G[\text{MMscfd}]\,MF}{\rho[\text{lb/gal}]\,WF\,AG},\ k = 112\ (\text{MEA}),\ 192\ (\text{DEA})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_G\) | Gas flow to the contactor | Nm³/s |
| \(MF\) | Acid gas (H₂S + CO₂) in the inlet gas | - |
| \(\text{amine}\) | Amine | - |
| \(WF\) | Amine strength in the solution | - |
| \(\rho\) | Solution density at 60 °F | kg/m³ |
| \(AG\) | Acid gas loading (mol acid gas per mol amine) | - |
| \(\text{excess}\) | Excess circulation margin | - |
| \(Q\) | Solution circulation (no margin) | m³/s |
| \(Q_{design}\) | Design circulation with margin | m³/s |
| \(\dot n_{AG}\) | Acid gas removed | mol/s |
| \(M\) | Molar mass of the amine | kg/kmol |
| \(\dot m_{amine}\) | Amine circulated (100 % basis) | kg/s |
Method and standards
Acid-gas mole balance (Arnold and Stewart).
Where it is used
- Sizing amine pumps and regenerators.
- Checking operating circulation.
Common mistakes
- Using percent instead of mole fraction for acid gas.
- Ignoring the lean loading of the regenerated amine.
Assumptions and limits
- Lean loading taken as zero; all acid gas absorbed.
References
- IUPAC standard atomic weights (amine molar masses)
Questions and answers
Where do the constants 112 and 192 come from?
They are 1.83 times the molar masses of MEA and DEA: moles of acid gas per day, divided by the loading, times the amine molar mass, converted to gallons per minute.
Why not run a higher loading?
Rich loadings above the guideline values make the solution corrosive, especially with CO₂.
What do the defaults represent?
50 MMscfd with 2 % acid gas treated with 20 wt % MEA (8.41 lb/gal) at 0.33 mol/mol: about 201 US gpm before the 10 % margin.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mokhatab, Poe and Speight, Handbook of Natural Gas Transmission and Processing (Gulf Professional Publishing, 2006), ch. 7, eqs. 7-16 and 7-17 (Arnold and Stewart, 1999; GPSA design loadings)