Worked example
Example: 1.2 MW of a 2 MW set. The inputs, in the units selected above:
| Input | Value |
|---|---|
| No-load steam flow | 1.2000 t/h |
| Full-load steam flow | 10.000 t/h |
| Full-load output | 2,000.0 kW |
| Load of interest | 1,200.0 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam flow at the load | 6.4800 t/h |
| Specific steam consumption | 5.4000 kg/kWh |
| Full-load specific steam consumption | 5.0000 kg/kWh |
Open this example in the calculator and change any input.
Formula
\(\dot m = \dot m_0 + (\dot m_1 - \dot m_0)\frac{P}{P_1}, \quad SSC = \frac{\dot m}{P}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_0\) | No-load steam flow | kg/s |
| \(\dot m_1\) | Full-load steam flow | kg/s |
| \(P_1\) | Full-load output | W |
| \(P\) | Load of interest | W |
| \(\dot m\) | Steam flow at the load | kg/s |
| \(SSC\) | Specific steam consumption | kg/J |
| \(SSC_1\) | Full-load specific steam consumption | kg/J |
Method and standards
Willans line.
Where it is used
- Captive turbine planning.
- BOE examinations.
Common mistakes
- Extrapolating beyond full load.
- Applying to nozzle-governed sets.
Assumptions and limits
- Throttle governing.
- At no load the steam rate is unbounded and not shown; a load above full load is an extrapolation and is flagged.
References
- Willans line: steam flow linear in load for throttle governing (steam turbine texts)
Questions and answers
1.2 t/h at no load, 10 t/h at 2 MW: at 1.2 MW?
6.48 t/h, 5.40 kg/kWh against 5.00 at full load.
Why does steam rate rise at low load?
The no-load flow is spread over less output.
Nozzle governing?
Flatter part-load curve; one line per nozzle group.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.