FireCADCalc

Willans Line: Steam Consumption at Part Load

Steam consumption of a turbine at any load from its no-load and full-load steam flows (Willans line), with the steam rate per kWh at that load.

Thermal power plantSugar mill and cogenerationPulp and paperBoiler operation engineer (BOE) examinations

Inputs

Examples: 1.2 MW of a 2 MW setNo load

Results

Holds for throttle-governed turbines; nozzle-governed machines follow a series of lines.

Steam flow at the load6.4800t/h
Specific steam consumption5.4000kg/kWh
Full-load specific steam consumption5.0000kg/kWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1.2 MW of a 2 MW set. The inputs, in the units selected above:

InputValue
No-load steam flow1.2000 t/h
Full-load steam flow10.000 t/h
Full-load output2,000.0 kW
Load of interest1,200.0 kW

Applying the formula below gives:

ResultValue
Steam flow at the load6.4800 t/h
Specific steam consumption5.4000 kg/kWh
Full-load specific steam consumption5.0000 kg/kWh

Open this example in the calculator and change any input.

Formula

\(\dot m = \dot m_0 + (\dot m_1 - \dot m_0)\frac{P}{P_1}, \quad SSC = \frac{\dot m}{P}\)

Variables

Symbol Meaning SI unit
\(\dot m_0\) No-load steam flow kg/s
\(\dot m_1\) Full-load steam flow kg/s
\(P_1\) Full-load output W
\(P\) Load of interest W
\(\dot m\) Steam flow at the load kg/s
\(SSC\) Specific steam consumption kg/J
\(SSC_1\) Full-load specific steam consumption kg/J

Method and standards

Willans line.

Where it is used

  • Captive turbine planning.
  • BOE examinations.

Common mistakes

  • Extrapolating beyond full load.
  • Applying to nozzle-governed sets.

Assumptions and limits

  • Throttle governing.
  • At no load the steam rate is unbounded and not shown; a load above full load is an extrapolation and is flagged.

References

  • Willans line: steam flow linear in load for throttle governing (steam turbine texts)

Questions and answers

1.2 t/h at no load, 10 t/h at 2 MW: at 1.2 MW?

6.48 t/h, 5.40 kg/kWh against 5.00 at full load.

Why does steam rate rise at low load?

The no-load flow is spread over less output.

Nozzle governing?

Flatter part-load curve; one line per nozzle group.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.